Cold-formed steel column calculator

ColdCalc finds the available axial strength of a cold-formed steel column, post or stud to AISI S100-24 and checks it against your loads. It covers flexural, torsional and flexural-torsional buckling, local and distortional buckling from a finite strip analysis of the section, eccentric loads and bracing at intervals.

Open the calculatorStart with a 7-day free trial of Pro. Nothing to install.

What you get

This is the result for the design the calculator opens on, computed by the ColdCalc engine when this page was built. Change any input in the calculator and it reruns in about a second.

CheckS100-24Ratio
Axial compression
0.00 ft, 1.2D + 1.6L
§E2, §E3.2, §E40.53OK

600S162-54, Fy = 50 ksi, 12 ft tall. AISI S100-24 LRFD, Direct Strength Method, finite strip buckling. A ratio is demand over available strength, or an interaction value over its limit; 1.00 or less passes.

What it checks

CheckWhat it coversAISI S100-24
Global bucklingFlexural, torsional and flexural-torsional buckling with the effective lengths the bracing gives§E2
Local buckling with global bucklingBy the Direct Strength Method or the Effective Width Method§E3
Distortional bucklingFrom the finite strip buckling load of the section§E4
Axial and bending combinedWhen the load is eccentric, with P-δ amplification§H1.2, §C1.2.1.1
TensionYielding and rupture, when a combination puts the member in tension§D2, §D3

Every check opens to its limit states, each intermediate value with its equation number, and the φ or Ω applied. Strengths come from the Direct Strength Method by default, or the Effective Width Method, in LRFD or ASD.

What you enter

  • An SSMA section or a custom C, Z, track or hat, and its steel grade
  • Height and end conditions
  • Axial loads by source: dead, live, roof, snow, wind
  • Eccentricity, where the load bears on a flange or off the centroid
  • Bracing points along the height, for each direction and for twist

How to use it

  1. 1Open the calculator and choose Column.
  2. 2Pick the section and set the height and end conditions.
  3. 3Enter the axial loads by source, and an eccentricity if the load is not concentric.
  4. 4Add bracing points for weak-axis buckling and twist.
  5. 5Read the governing limit state and open it to see every value and equation.

Questions

How do you calculate the axial capacity of a cold-formed steel stud?

Take the smallest of three nominal strengths in AISI S100-24 Chapter E: global buckling (E2), local buckling interacting with global buckling (E3) and distortional buckling (E4). Multiply by φc = 0.85 for LRFD or divide by Ωc = 1.80 for ASD. The elastic buckling loads behind E3 and E4 come from a finite strip analysis or the closed-form solutions of Appendix 2.

Why does a C-section column fail by flexural-torsional buckling?

A C-section has one axis of symmetry, so its shear center is not at its centroid. Buckling about the axis of symmetry is coupled with twisting, and the flexural-torsional buckling load is lower than either the flexural or the torsional load alone. Bracing against twist raises it.

What K factor does the calculator use?

The member analysis works from the supports and braces you draw, so the buckling lengths follow from them: pinned ends give K = 1 between braces. In Known forces you can type KxLx, KyLy and KtLt directly.

Does it include distortional buckling?

Yes. The finite strip analysis finds the distortional buckling load of the actual section, and Section E4 turns it into a strength. Distortional buckling often governs lipped C-sections with narrow lips or high-strength steel.

ColdCalc is a design aid. AISI S100-24 is the governing text, and results must be reviewed by the engineer responsible for the design. How the engine is tested against published examples, SSMA tables, CUFSM results and CFS reports is on the validation section of the home page.

How the checks work