Cold-formed steel connection calculator: screws, bolts and welds

ColdCalc checks cold-formed steel connections to Chapter J of AISI S100-24. Choose screws, bolts, power-actuated fasteners or a weld type, enter the two connected sheets and the forces, and it reports every limit state with its nominal strength, safety or resistance factor and equation, plus the spacing and edge-distance rules.

Open the calculatorStart with a 7-day free trial of Pro. Nothing to install.

What you get

This is the result for the design the calculator opens on, computed by the ColdCalc engine when this page was built. Change any input in the calculator and it reruns in about a second.

Limit stateS100-24Nominal, kipφAvailable, kip
Screw tilting and bearing§J4.3.12.080.551.15

2 screws joining a 0.0451 in. sheet (Fu = 45 ksi) to a 0.0566 in. sheet (Fu = 65 ksi), with 0.50 kip of shear. AISI S100-24 LRFD. The connection works at 0.44 of its available strength.

What it checks

CheckWhat it coversAISI S100-24
Screws in shearTilting and bearing of the sheets, and shear of the screw§J4.3
Screws in tensionPull-out from the sheet not in contact with the head, pull-over of the sheet under the head, and tension of the screw§J4.4
Screws in shear and tensionCombined shear and pull-over, shear and pull-out, and shear and tension in the screw§J4.5
BoltsBearing with or without hole deformation, bolt shear and tension, spacing and edge distance§J3
Power-actuated fastenersTension, pull-out, pull-over, shear, bearing and tilting§J5
WeldsGroove, arc spot and plug, arc seam, top arc seam sidelap, fillet, flare-groove and resistance welds§J2
Spacing and edge distanceMinimum spacing and edge distance of screws, bolts and power-actuated fasteners§J3.1, §J3.2, §J4.1, §J4.2, §J5.1

Every check opens to its limit states, each intermediate value with its equation number, and the φ or Ω applied. Strengths come from the Direct Strength Method by default, or the Effective Width Method, in LRFD or ASD.

What you enter

  • The connection type: screws, bolts, power-actuated fasteners, or one of seven weld types
  • The two connected sheets: thickness and steel grade of each
  • Fastener size, head or washer diameter, and number of fasteners
  • Spacing and edge distance
  • Required shear and tension on the connection
  • The fastener's own shear and tension strength from the manufacturer, where the Specification needs it

How to use it

  1. 1Open the calculator and choose Connection.
  2. 2Pick the fastener or weld type.
  3. 3Enter the thickness and grade of each sheet; sheet 1 is the one under the screw head.
  4. 4Enter the fastener size, the number of fasteners, the spacing and the edge distance.
  5. 5Enter the required shear and tension, and read each limit state with its equation.

Questions

How do you calculate the shear strength of a screw connection in cold-formed steel?

AISI S100-24 Section J4.3.1 gives the nominal shear strength per screw as limited by tilting and bearing of the connected sheets. When the sheet away from the head is no thicker than the one under it (t2/t1 ≤ 1.0), it is the smallest of 4.2(t2³d)^0.5·Fu2 (tilting), 2.7·t1·d·Fu1 and 2.7·t2·d·Fu2 (bearing). When t2/t1 ≥ 2.5 only the two bearing equations apply, and between the two ratios the strength is interpolated. The screw's own shear strength (J4.3.3, from the manufacturer) is checked as well when you enter it. Rupture of the sheets (J6) is a separate check.

What is the difference between pull-out and pull-over?

Pull-out is the screw threads stripping out of the sheet they are driven into: Pnot = 0.85·tc·d·Fu2·[1.63(α·tc)^0.18] (Eq. J4.4.1-1, with a thickness term that is new in S100-24). Pull-over is the sheet under the head tearing over the head or washer: Pnov = 1.5·t1·d′w·Fu1 (Eq. J4.4.2-1). Tension on a screw connection is limited by the smaller of the two and by the screw's own tensile strength.

What are the minimum spacing and edge distance for screws?

AISI S100-24 Sections J4.1 and J4.2 require a center-to-center spacing of at least 3 screw diameters and a distance from the center of a screw to any edge of at least 1.5 diameters. ColdCalc checks both and flags a connection that does not meet them.

Which weld types does the calculator cover?

Groove welds in butt joints (J2.1), arc spot welds (J2.2) and arc plug welds (J2.5), arc seam welds (J2.3), top arc seam sidelap welds (J2.4), fillet welds (J2.6), flare-groove welds (J2.7) and resistance welds (J2.8).

Does it check block shear?

Not in the calculator yet. It checks the fastener or weld limit states and the minimum spacing and edge distances. Rupture of the connected parts to Section J6 (shear rupture, tension rupture and block shear) is a separate check for now.

ColdCalc is a design aid. AISI S100-24 is the governing text, and results must be reviewed by the engineer responsible for the design. How the engine is tested against published examples, SSMA tables, CUFSM results and CFS reports is on the validation section of the home page.

How the checks work