SpecificationIntermediate12 min read

What changed in AISI S100-24: a guide for designers

The changes in the 2024 North American Specification that affect everyday member design: new DSM equations, flexure up to Mp, shear, torsion and bimoment, and how much answers move.

By ColdCalc Engineering
In short
  • AISI S100-24 (ANSI/SDI AISI S100-2024) is the 2024 North American Specification for the Design of Cold-Formed Steel Structural Members. The Steel Deck Institute (SDI) published it, first printing December 2024, as a free download from sdi.org. It revises S100-16(R2020) with Supplement 3 (S3-22).
  • The headline change is that every Direct Strength Method (DSM) strength curve is now one rational equation. Column strengths barely move. Beam strengths now run from the plastic moment Mp up to a cap My3, with new factors αs and βs for the shape of the section.
  • DSM lateral-torsional buckling (§F2.2) and web shear (§G2) use the same kind of equation. In shear, slender webs gain a post-buckling strength that S100-16 as first published did not give them, while stocky webs lose a little.
  • Several changes often credited to S100-24 arrived in 2022 with Supplement 3: bimoment strength (§G8), the bending–torsion interaction (§H4), the post-buckling shear format and Appendix 2 §2.3. If your last edition was S100-16 without S3-22, you get both sets at once.
  • The 2024 IBC references S100-16(2020) with S2-20. S100-24 is expected in the 2027 I-Codes. Design to the edition your jurisdiction's code references.

The document#

The full title is ANSI/SDI AISI S100-2024, North American Specification for the Design of Cold-Formed Steel Structural Members, 2024 Edition. SDI took over AISI's cold-formed steel standards in 2023 and announced the new edition on March 5, 2025. It keeps the chapter layout S100-16 introduced (Chapters A to M), now with Appendices 1 to 5 and the country appendices A and B.

The preface says only that the standard "is a revision of ANSI/AISI S100-2016(R2020)w/S3-2022"; it does not list the changes. The list below therefore comes from the Specification and Commentary themselves. The Commentary often dates a change ("In 2024, …" or "In 2022, …"), and every statement here about the 2024 text was checked against it. Where we rely on a summary instead, such as the Cold-Formed Steel Research Consortium's (cfsrc.org) or a software vendor's, we say so.

We sort the changes into three groups:

  1. New in S100-24, confirmed in the 2024 Specification and Commentary.
  2. Arrived with Supplement 3 (S3-22) to S100-16 and carried into S100-24. Designers moving from plain S100-16 will see these too.
  3. Things to check yourself, where the sources are thin or a rule of thumb no longer holds.

New in S100-24: the DSM strength equations#

One rational form for every curve

Since 2004 the DSM curves had the form of Winter's plate equation, a power of Pcr/Py. S100-24 replaces them with a ratio of two quadratics in the slenderness. For columns:

Pnℓ = 1.2 Pne (1 + 0.10λℓ2) / (1 + 0.55λℓ2) ≤ Pne
Eq. E3.2-1, λℓ = √(Pne/Pcrℓ)
Pnd = 1.2 Py (1 + 0.05λd2) / (1 + 0.67λd2) ≤ Py
Eq. E4-1, λd = √(Py/Pcrd)

The Commentary credits the new form to Glauz (2023) and describes it as "providing equivalent strength predictions." The plots bear that out:

0.00.20.40.60.81.001234slenderness λℓS100-24S100-16600S162-54: λ = 1.89, 0.55
Direct Strength Method local buckling strength of columns: Pnℓ/Pne against λℓ = √(Pne/Pcrℓ). Solid: AISI S100-24 Eq. E3.2-1. Dashed: the AISI S100-16 equation it replaced. The dot is the 600S162-54 as a short column (Pne = Py).
0.00.20.40.60.81.001234slenderness λdS100-24S100-16600S162-54: λ = 1.48, 0.54
Direct Strength Method distortional buckling strength of columns: Pnd/Py against λd = √(Py/Pcrd). Solid: AISI S100-24 Eq. E4-1. Dashed: the AISI S100-16 equation it replaced. The dot is the 600S162-54 as a short column (Pne = Py).

Up to a slenderness of 4, the new local curve stays within about 4.5 % of the old one, and the distortional curve within about 2.5 %. The largest local difference is just past the old plateau. S100-16 gave the full Pne up to λℓ = 0.776, while Eq. E3.2-1 reaches its cap only for λℓ ≤ 0.68, so it is lower in between.

At high slenderness the rational form levels off instead of falling to zero. The equations apply for λ ≤ 5, and a User Note points to the Commentary, which offers limits that fall toward zero for the rare sections beyond.

Run through actual sections, the change is small. These are short columns, so Pne = Py, with the same finite strip buckling loads in both editions:

SectionFy, ksiλℓλdS100-16S100-24Change
362S162-33331.541.025.465.56+2 %
362S162-54501.150.9516.2916.51+1 %
600S162-54501.891.4814.6815.02+2 %
600S200-97501.050.9541.7141.740 %
800S200-54502.511.8315.4415.67+1 %
1000S162-43333.182.655.925.87−1 %
1200S162-54503.823.539.319.320 %

Pn in kip

Short columns (Pne = Py): nominal axial strength Pn = min(Pnℓ, Pnd). S100-16: the power-law forms of Sections E3.2.1 and E4.1. S100-24: Eqs. E3.2-1 and E4-1. Illustration of the base strength-equation change only: each row uses the same section, Fy and finite strip buckling values in both editions, with no holes and no cold work of forming. Computed by ColdCalc.

Beams: from Mp, with αs, βs and My3

Flexure is where the answers move. S100-16 based DSM bending on the yield moment My and treated strength above it as optional inelastic reserve. S100-24 builds the reserve into a single curve that starts from the plastic moment:

Mnℓ = ks M̄ne (1 + 0.10αsλℓ2) / (1 + 0.55βsλℓ2) ≤ My3
Eq. F3.2-1, λℓ = √(M̄ne/Mcrℓ)
Mnd = Mp (1 + 0.07αsλd2) / (1 + 0.60βsλd2) ≤ My3
Eq. F4-1, λd = √(My/Mcrd)

where:

  • M̄ne is the lesser of Mne and My.
  • ks = Mp/My (Eq. F3.2-3) is the shape factor, so ksM̄ne = Mp for a fully braced beam.
  • αs is 1 for sections with corners at the extreme compression fiber and 0 otherwise. In §F4 the corners must also not translate in distortional buckling. Sections with corners between the extreme fibers may take 0 conservatively; the Commentary suggests interpolating ds/d.
  • βs = 2yc/d ≥ 0.4 (Eqs. F3.2-4 and F4-3) is 1 for sections symmetric about the bending axis. It is above 1 when the section yields first in compression, which is unfavourable.
  • My3 = Mp − (Mp − My)/9 (Eq. F3.2-5) is the "member moment at strain limit," the ceiling on both.

Set ks = 1.2 and αs = βs = 1 and Eq. F3.2-1 has the same form as the column equation E3.2-1. The 1.2 in the column equations acts like a shape factor.

0.00.20.40.60.81.01.21.40.00.51.01.52.02.53.0local slenderness λℓ = √(My/Mcrℓ)S100-16αs = 1, βs = 1αs = 0βs = 1.3
Local buckling strength of a fully braced beam, Mnℓ/My against λℓ = √(My/Mcrℓ), for Mp/My = 1.2. Solid: S100-24 Eq. F3.2-1, capped at My3 (Eq. F3.2-5), for a section with corners at the compression fiber that is symmetric about the bending axis (αs = 1, βs = 1), one without such corners (αs = 0), and one that yields first in compression (βs = 1.3). Dashed: S100-16 Section F3.2.1, which stopped at My.

For a typical lipped C with Mp/My near 1.2, My3 is about 1.18My. A stocky, fully braced stud can now be assigned up to about 18 % more than My without a separate inelastic reserve check. Just past the old plateaus, though, the new curves sit a few percent below the old ones. Across real sections the effect goes both ways:

SectionλℓλdMp/MyS100-16S100-24ChangeS100-24 governs
362S162-330.750.751.1549.49.0−5 %F4 distortional
362S162-540.560.701.16323.622.4−5 %F4 distortional
600S162-540.810.831.19642.142.20 %F4 distortional
600S200-970.460.601.19193.593.90 %F4 distortional
800S200-541.080.981.19965.166.8+3 %F4 distortional
1000S162-431.351.141.24336.838.9+6 %F3.2 local
1200S162-541.591.471.26675.983.3+10 %F4 distortional

Mn in kip·in

Strong-axis bending, compression flange braced: nominal strength Mn = min(Mnℓ, Mnd). S100-16: Sections F3.2.1 and F4.1 with Mne = My (no inelastic reserve). S100-24: Eqs. F3.2-1 and F4-1 with Mne = Mp, capped at My3, run by the engine. Illustration of the base strength-equation change only: each row uses the same section, Fy and finite strip buckling values in both editions, with no holes and no cold work of forming. Computed by ColdCalc. S100-16's optional DSM inelastic reserve (local for λℓ ≤ 0.776, distortional for λd ≤ 0.673) would raise the S100-16 value for 600S200-97 (to 95.5 kip·in); for the others it does not change the governing S100-16 value.

Narrow, stocky studs governed by distortional buckling lose a few percent. Deep, slender joists gain up to about 10 %. Two limits still apply: if the yield stress includes cold work of forming, Mne may not exceed My (§F2.2); and the Effective Width Method (§F3.1) is still capped at the first-yield value unless you use the inelastic reserve of §F2.1.1. The EWM vs DSM article covers how that widens the gap between the methods.

Lateral-torsional buckling in the DSM

S100-16 took the DSM global strength from the Effective Width Method's stress Fn, capped at My. The Commentary records that this "resulted in discontinuities for strengths above My" for sections unsymmetric about the bending axis. S100-24 §F2.2 returns to the 2012 equation, with Mp in place of the old (10/9)My:

Mne = Mp(1 − 0.25Mp/Mcre) for Mcre > 0.5Mp;   Mne = Mcre otherwise;   Mp = ZfFy
Eqs. F2.2-1 to F2.2-3
0.00.20.40.60.81.01.21.40.00.51.01.52.0global slenderness λe = √(My/Mcre)S100-16S100-16 inelastic reserveS100-24
Global (lateral-torsional) buckling strength Mne/My of a Direct Strength Method beam against λe = √(My/Mcre), for the 600S162-54 (Mp/My = 1.196 from ColdCalc). Solid: S100-24 Eq. F2.2-1 and F2.2-2. Dashed: S100-16, which used the Effective Width Method stress Fn of Section F2.1 (Mne ≤ My). Dotted: the optional S100-16 inelastic reserve for λe ≤ 0.60.

Mne passes My once Mcre exceeds 0.25ks2/(ks − 1) times My, which is 1.8My for ks = 1.2. Under S100-16, without the optional reserve, Mne reached My only at Mcre = 2.78My. The gain grows as bracing improves, though for well-braced members local or distortional buckling usually governs instead.

New in S100-24: shear, torsion and the rest#

Web shear

The shear strength of a web without stiffeners is now one equation (§G2.1):

Vn = 1.2Vy / (1 + 0.57λv2) ≤ Vy,   λv = √(Vy/Vcr),   Vy = 0.6htFy
Eqs. G2.1-1 to G2.1-3

Webs with transverse stiffeners that meet §G2.2 use Vn = 1.2Vy(1 + 0.05λv2)/(1 + 0.45λv2) ≤ Vy (Eq. G2.2-1). The history spans two editions. Supplement 3 (2022) moved §G2.1 to a DSM format with shear post-buckling, and changed the factors to Ω = 1.67 and φ = 0.90 (LRFD). S100-24 recalibrated both equations to the present form (Glauz 2023).

Compared with S100-16 as first published, which had three ranges and no post-buckling, the effect depends on the web:

SectionλvS100-16S100-24Change
362S162-331.161.641.58−3 %
362S162-540.865.404.80−11 %
600S162-541.474.525.23+16 %
600S200-970.7816.7514.89−11 %
800S200-541.983.354.86+45 %
1000S162-432.551.342.22+66 %
1200S162-543.002.203.88+76 %

Vn in kip

Web shear without stiffeners or holes: nominal strength Vn of one web, kv = 5.34. S100-16 (as first published, before Supplement 3): the three ranges of Section G2.1. S100-24: Eq. G2.1-1. Nominal values; the ASD safety factor also rose from 1.60 to 1.67. Illustration of the base strength-equation change only: each row uses the same section, Fy, Vy and Vcr (Eqs. G2.1-3 and G2.3-1) in both editions, with no holes and no cold work of forming. Computed by ColdCalc.

Equation G2.1-1 reaches Vy only for λv ≤ 0.59, where S100-16 held Vy up to 0.815. Stocky webs therefore lose up to about 13 % of nominal strength, plus about 4 % in ASD from the larger Ω. Slender webs, where S100-16 gave only the elastic buckling force, gain a great deal. Use Vn from the current equation; tables built on the old one can be wrong in both directions.

Torsion: bimoment strength and §H4

§G8.1 gives the nominal bimoment strength as the first-yield value, Bn = By = FyCw/ωn,max (Eqs. G8.1-1 and G8.1-2), a provision that arrived with S3-22. S100-24 also permits an alternative with inelastic reserve, limited by buckling of the web or flange under the bimoment stress:

  • web modes: Bn = Bp(1 + 0.09λw2)/(1 + 0.23λw2), with λw = √(By/Bcrw) (Eqs. G8.1-3, -4);
  • flange modes: Bn = Bp/(1 + 1.11λf2), with λf = √(By/Bcrf) (Eqs. G8.1-5, -6).

Bp is the plastic bimoment, and Bcrw and Bcrf come from a rational elastic buckling analysis under bimoment stress, such as a finite strip analysis. The Commentary credits the method to Xia et al. (2022).

Combined bending and torsion is checked with a linear interaction:

M̄x/Max + M̄y/May + B̄/Ba ≤ 1.0
Eq. H4-1

Here M̄x, M̄y and B̄ are the required strengths, and Max, May and Ba the available strengths from Chapter F and §G8.1.

For C-sections where the bimoment puts the free edge of the compression flange in tension, and for Z-sections where it puts the free flange edges in tension, the limit may rise to 1.25. At a discrete lateral-torsional brace, Ma need not be reduced for lateral-torsional buckling. The Commentary dates the linear form to 2022. In 2024 it was "refined based on the research by Xia et al. (2023) to utilize the bimoment buckling strength with inelastic reserve and to consider the flexural failure modes of lateral-torsional buckling and distortional buckling." §H4 does not apply when §I6.2.1 or §I6.2.2 is used, which matters for purlins (see lapped Z-purlins).

Smaller changes worth knowing

  • Appendix 5, Evaluation of Existing Structures, is new. It covers evaluation by analysis, by load tests, or both, under static loads.
  • Appendix 4, fire. It lets fire resistance be shown by analysis, or by analysis combined with testing, as well as by traditional qualification testing. cfsrc.org describes these as the first performance-based fire design provisions in the U.S. standard.
  • Appendix 3, beam-columns. This optional alternative to the §H1 interaction equations checks the member under the actual combination of forces. Per the Commentary, the 2024 strength curves let it use a single equation per mode. That matches cfsrc.org's mention of "simplifications for direct design of beam columns."
  • §G4.1 transverse web stiffeners now follow the AISC 360-16 requirements, for full tension field action only.
  • §I4.1, all-steel design of wall stud assemblies, was removed from S100. All-steel design remains valid and is covered by AISI S240.
  • Welds (§J2.2.1, §J2.3.1): rupture must now be checked in addition to the minimum edge and end distance.
  • Appendix 2 §2.3.3.3: the reduced web thickness tr for web holes was clarified for a single hole or a single line of holes.

Arrived with Supplement 3 (S3-22)#

S3-22 was a large supplement, and S100-24 carries it forward. If your office skipped it, these are changes too. Items marked † are dated to 2022 in the S100-24 Commentary; the others come from the public summaries of S3-22.

  • Appendix 2 §2.3: the analytical global buckling solutions moved there from §E2 and §F2.1.† The Cb factor replaced 1/CTF.† New global buckling solutions were added for non-symmetric sections, along with Mcrd about an axis parallel to the web.
  • §E4 and §F4: DSM distortional buckling extended to U-sections, hats and panels.
  • §G2: shear in DSM format with post-buckling; Ω = 1.67, φ = 0.90.† Webs with holes (§G3) revised.
  • §G8 and §H4: the torsion bimoment strength and the linear bending–torsion interaction.†
  • §G7: bearing stiffeners moved there from §F5.
  • §I1.2, built-up compression members: generalized, with the stiffness reduction now a reduced moment of inertia instead of an increased effective length.†
  • §C2.2 and §C2.3: beam bracing, and bracing of multiple compression members.
  • §B4.1: limits clarified, separating shear and web crippling limits from buckling limits.†
  • §A3.1: ASTM A463, A1018, A1046, A1079, A1083 and A1088 added.† For low-ductility steels (§A3.1.3), the tensile strength used in design rose to 80 % of the specified minimum, up to 65 ksi.†
  • Appendix 1 §1.1.3: webs with holes take the stress gradient into account, worth up to about 2 % for common C-sections.†
  • Connections: recalibrated weld factors,† arc plug welds (§J2.5), double shear (§J4.3.2), SAE bolts and block shear (§J6.3).

Vendor lists mix the groups. RSG's list of S100-24 features for CFS 15 includes the A1079 and A1088 grades, which the Commentary dates to 2022.

Things to check yourself#

  • Built-up members and bracing. cfsrc.org lists built-up member design and bracing design among the 2024 improvements. The only dated change we found in the Commentary is the 2022 reduced moment of inertia for built-up columns, and the §C2 text carries no 2024 date. Compare §I1 and §C2 with the edition you know before relying on either.
  • Old screening limits. Appendix 2 Commentary §2.2.3 still says no local reduction occurs when Pcrℓ > 1.66Py. That threshold comes from the S100-16 curve. Under Eq. E3.2-1 the full strength needs Pcrℓ ≥ 2.15Pne, and a column with Pcrℓ = 1.8Py loses about 3 %. The distortional threshold, 3.18Py, remains safe.
  • A Commentary figure label. The inset of Figure C-F4-2 shows the coefficients 0.10 and 0.55. The Specification's Eq. F4-1 uses 0.07 and 0.60. Use the Specification.
  • αs for unusual shapes. For sections with corners between the extreme fibers, αs = 0 is always permitted. A rational value needs justification.
  • Your software and your spreadsheets. Check which edition a program implements. As of October 2026, besides ColdCalc, RSG's CFS 15 is the only design program we found that claims S100-24; see our software comparison. Spreadsheets and load tables built on S100-16 DSM equations need updating, especially for shear and bending.

What it means for a project today#

Start with the building code. The 2024 International Building Code references AISI S100-16(2020) with Supplement 2 (S2-20). Supplement 3 is not part of that reference, so a project under the 2024 IBC is designed to S100-16 without the S3-22 changes. S100-24 is expected to be referenced in the 2027 I-Codes, but check what your jurisdiction actually adopts, and when.

Using S100-24 on a project whose code references S100-16 generally needs the building official's acceptance as an alternative design method. Practically:

  • Under the 2024 IBC or earlier: design to S100-16(2020) w/S2-20 and expect your reviewer to check against it. Use S100-24 to understand where the next code will move your members, especially deep joists in shear and braced beams in bending.
  • When S100-24 is adopted: re-check standard details and tables. The changes are mostly modest for columns but run in both directions for shear and braced bending.
  • For research, testing or manufacturer evaluations: S100-24 is the current state of the art, and its Commentary gives the background for each change.

For the full DSM procedure with the new equations, see the Direct Strength Method worked example. For the bigger picture, see the cold-formed steel design guide.

What is the difference between AISI S100-16 and S100-24?

S100-24 rewrites every Direct Strength Method strength curve in one rational form. Beam strengths now run from the plastic moment Mp up to My3, with factors alpha-s and beta-s. DSM lateral-torsional buckling and web shear use the same kind of equation. S100-24 also adds an alternative bimoment strength with inelastic reserve, refines the bending-torsion interaction, and adds Appendix 5 for existing structures. Many other changes, such as the bimoment strength and the reorganized Appendix 2, came earlier with Supplement 3 (S3-22) to S100-16.

Is AISI S100-24 adopted in the IBC?

Not in the 2024 IBC, which references AISI S100-16(2020) with Supplement 2 (S2-20). S100-24 is expected to be referenced in the 2027 International Codes, but adoption depends on each jurisdiction. Check the edition your local building code references before designing to S100-24.

Where can I download AISI S100-24?

The Steel Deck Institute (SDI), which now publishes the AISI cold-formed steel standards, offers ANSI/SDI AISI S100-2024 as a free download from sdi.org.

Did the Direct Strength Method change in AISI S100-24?

Yes. The local and distortional strength equations (Eqs. E3.2-1, E4-1, F3.2-1 and F4-1) now use a ratio of quadratics in the slenderness instead of the old power-law form. For columns the predictions are nearly the same. For beams the strength now runs from Mp, capped at My3 = Mp - (Mp - My)/9, so fully braced beams can exceed My without a separate inelastic reserve check.

What are alpha-s and beta-s in AISI S100-24?

They are factors in the DSM bending equations F3.2-1 and F4-1. Alpha-s is 1 when the section has corners at the extreme compression fiber (that do not translate, for distortional buckling) and 0 otherwise. Beta-s equals 2yc/d, not less than 0.4: 1 for sections symmetric about the bending axis, and above 1 when first yield is in compression.

Numbers in this article are computed by the ColdCalc engine when the page is built, so they match what the calculator gives today. AISI S100-24 is the governing text; ColdCalc is a design aid, and its results should be reviewed by the engineer responsible for the design.