How to read an SSMA stud designation: 600S162-54 explained
What each part of an SSMA designation like 600S162-54 means: depth, style, flange width and mils, with design thicknesses, lip lengths, bend radii and the section's properties.
- An SSMA designation has four parts: depth, style, flange width and thickness. 600S162-54 is a 6.00 in deep (600) stud or joist with lipped flanges (S), 1-5/8 in flanges (162), made from 54 mil steel (54).
- Depth and flange width are in hundredths of an inch. Thickness is in mils, thousandths of an inch, and is the minimum uncoated steel thickness, not the thickness you design with.
- The design thickness is the minimum divided by 0.95, because AISI S100-24 §B7.1 lets delivered steel be as thin as 95 % of the design thickness. For 54 mil that is 0.0566 in.
- The style letters are S (stud or joist, with lips), T (track, no lips), U (channel) and F (furring channel). A track's depth is its inside dimension, so a 600T track fits around a 600S stud.
- The designation does not give the steel grade. Studs and joists are usually 33 ksi below 54 mil and 50 ksi from 54 mil up, but the drawings must say which.
Cold-formed steel framing members are named with a short code that spells out their size: 362S162-33, 600S162-54, 800T125-43. The system comes from the Steel Stud Manufacturers Association (SSMA) Product Technical Guide, and manufacturers, specifiers and design software use it to describe the same section in the same words. Once you can read it, you can picture the cross-section and work out the dimensions you need for design.
This article takes the designation apart, gives the tables of thicknesses, flange widths and lip lengths that ColdCalc builds its sections from, and decodes a few common members.
The four parts of a designation#
| Part | In 600S162-54 | Meaning | Unit |
|---|---|---|---|
| Depth | 600 | 6.00 in member depth | 1/100 in |
| Style | S | Stud or joist: a C-section with lipped flanges | letter |
| Flange width | 162 | 1.625 in (1-5/8 in) flange | 1/100 in |
| Thickness | 54 | 54 mil minimum base steel thickness, 0.054 in | 1/1000 in (mil) |
Read it left to right: a 6 inch stud with 1-5/8 inch flanges, 54 mil. The same rules apply to every size, so 1000S200-68 is a 10 in joist with 2 in flanges, 68 mil.
Depth: the first number#
The first number is the member depth in hundredths of an inch: 600 is 6.00 in, 800 is 8.00 in, 1200 is 12.00 in. Sizes in eighths are truncated rather than rounded, so 3-5/8 in is written 362 (not 363) and 1-5/8 in is 162. A designation never uses a decimal point.
For a stud or joist (S), the depth is the out-to-out dimension of the web. For a track (T), it is the inside dimension between the flanges, as explained below.
Style: S, T, U and F#
The letter after the depth is the style, the kind of section:
- S: stud or joist. A C-shaped section with a lip on each flange. The same shape serves as a wall stud, a floor or roof joist, a rafter or a header. The lips stiffen the flanges, which matters for buckling.
- T: track. A C-shaped section with no lips. Tracks run along the top and bottom of a wall to hold the studs, and as rim members at the ends of joists.
- U: channel.
- F: furring channel.
ColdCalc's catalog lists the S and T styles. It doesn't list U or F sections. You can enter any other shape as a custom section in the calculator.
Flange width: the second number#
The number after the letter is the flange width in hundredths of an inch, measured out-to-out like the depth: 125 is 1-1/4 in, 162 is 1-5/8 in, 200 is 2 in. Studs and joists also carry a lip on each flange, and its length follows from the flange width. The tables below are the depths and flanges in ColdCalc's catalog, with the lip length each stud flange gets:
| Code | Inches | Fraction | Styles |
|---|---|---|---|
| 162 | 1.625 | 1-5/8 | S, T |
| 250 | 2.500 | 2-1/2 | S, T |
| 350 | 3.500 | 3-1/2 | S, T |
| 362 | 3.625 | 3-5/8 | S, T |
| 400 | 4.000 | 4 | S, T |
| 550 | 5.500 | 5-1/2 | S, T |
| 600 | 6.000 | 6 | S, T |
| 800 | 8.000 | 8 | S, T |
| 1000 | 10.000 | 10 | S, T |
| 1200 | 12.000 | 12 | S, T |
| 1400 | 14.000 | 14 | S, T |
| Code | Width, in | S lip, in | Styles |
|---|---|---|---|
| 125 | 1.250 (1-1/4) | 0.188 (3/16) | S, T |
| 137 | 1.375 (1-3/8) | 0.375 (3/8) | S |
| 150 | 1.500 (1-1/2) | – | T |
| 162 | 1.625 (1-5/8) | 0.500 (1/2) | S |
| 200 | 2.000 (2) | 0.625 (5/8) | S, T |
| 250 | 2.500 (2-1/2) | 0.625 (5/8) | S |
| 300 | 3.000 (3) | 0.625 (5/8) | S, T |
| 350 | 3.500 (3-1/2) | 1.000 (1) | S |
The lip is short, but it does real work. Without it, the flange tip is a free edge that buckles at a low stress. With it, the flange is supported on both edges, but if the lip is too short the flange and lip can rotate together about the web corner. That is distortional buckling, explained in the article on local, distortional and global buckling. Wider flanges get longer lips.
Thickness: mils, minimum and design#
The last number is the thickness in mils. One mil is a thousandth of an inch, so 54 mil is 0.054 in. It is the minimum thickness of the uncoated base steel, without the zinc coating.
You don't design with the minimum, but with the design thickness. AISI S100-24 §B7.1 says the uncoated steel thickness delivered to the site must not be less than 95 % of the thickness t used in design (bends may be thinner). Turning that around, the design thickness is the minimum thickness divided by 0.95. For 54 mil, the design thickness is 0.0566 in and the minimum is 0.0538 in.
| Mils | Minimum t, in | Design t, in | Inside radius R, in | Usual Fy, ksi |
|---|---|---|---|---|
| 18 | 0.0179 | 0.0188 | 0.0844 | 33 |
| 27 | 0.0269 | 0.0283 | 0.0796 | 33 |
| 30 | 0.0296 | 0.0312 | 0.0782 | 33 |
| 33 | 0.0329 | 0.0346 | 0.0765 | 33 |
| 43 | 0.0428 | 0.0451 | 0.0712 | 33 |
| 54 | 0.0538 | 0.0566 | 0.0849 | 50 |
| 68 | 0.0677 | 0.0713 | 0.1070 | 50 |
| 97 | 0.0966 | 0.1017 | 0.1526 | 50 |
| 118 | 0.1180 | 0.1242 | 0.1863 | 50 |
Thickness drives almost everything in a cold-formed section. Area and stiffness grow in proportion to it, but the resistance of a thin plate to local buckling grows with its square. Going from 33 mil to 54 mil adds close to two-thirds more steel, and much more than that in local buckling resistance.
Inside bend radius#
The corners of a roll-formed section are curved, and the radius matters: a larger radius shortens the flat widths that buckle, and it changes the area and the section properties slightly. ColdCalc uses an inside bend radius of
where t is the design thickness. In words, the centerline radius of the bend is never less than 3/32 in, and the inside radius is never less than one and a half thicknesses. The first term governs up to 43 mil; from 54 mil the 1.5t term governs. The radii are in the thickness table above.
The radius also matters for the Specification. Table B4.1-1 of AISI S100-24 limits the inside radius to R/t ≤ 10 for the Effective Width Method and R/t ≤ 20 for the Direct Strength Method, and the web crippling equation of §G5 includes R/t directly. ColdCalc models every corner as a true circular arc, so the properties include the rounded corners rather than a square-corner approximation.
Steel grade: 33 ksi and 50 ksi#
The designation says nothing about the grade of the steel. Framing members are usually made to ASTM A1003, whose structural grades ST33H and ST50H are listed among the applicable steels in AISI S100-24 §A3.1.1. ColdCalc assumes the grade most often supplied:
- 33 ksi (ST33H) for members thinner than 54 mil;
- 50 ksi (ST50H) for 54 mil and heavier.
That is ColdCalc's default, not a rule, and the grade varies by manufacturer. Specify the grade on the drawings, and check it against the manufacturer's data. The grade changes the strength of every member, and a 50 ksi assumption on a 33 ksi stud is unconservative.
Track depth is the inside dimension#
A track has to fit around the studs, so its depth is measured differently. For a T section, the depth in the designation is the inside dimension between the flanges. A 600T125-54 track has 6.00 in between the insides of its flanges, so a 600S stud (6.00 in out-to-out) slides in. Its outside depth is the inside depth plus two thicknesses: 6.00 in + 2 × 0.0566 in, about 6.11 in.
ColdCalc builds tracks this way: the web of a T section is the designation depth plus 2t, out-to-out. Track flanges come in their own widths, listed in the T column of the flange table above, including 1-1/2 in, which studs don't use.
Worked examples#
Here are three designations decoded into the geometry ColdCalc builds, with the area and weight its engine computes.
| 362S162-33 | 600S200-54 | 800T125-43 | |
|---|---|---|---|
| Style | S: stud or joist, with lips | S: stud or joist, with lips | T: track, no lips |
| Depth, in | 3.625 outside | 6.000 outside | 8.000 inside |
| Outside depth, in | 3.625 | 6.000 | 8.090 |
| Flange width, in | 1.625 (1-5/8) | 2.000 (2) | 1.250 (1-1/4) |
| Lip length, in | 0.500 (1/2) | 0.625 (5/8) | none |
| Minimum thickness, in | 0.0329 | 0.0538 | 0.0428 |
| Design thickness t, in | 0.0346 | 0.0566 | 0.0451 |
| Inside bend radius R, in | 0.0765 | 0.0849 | 0.0712 |
| Usual grade | 33 ksi | 50 ksi | 33 ksi |
| Area A, in² | 0.262 | 0.613 | 0.470 |
| Weight, lb/ft | 0.89 | 2.09 | 1.60 |
362S162-33. 362 is 3-5/8 in deep; S is a stud with lips; 162 is a 1-5/8 in flange with a 1/2 in lip; 33 mil gives a design thickness of 0.0346 in. It is a common wall stud size, usually in 33 ksi steel. Its area is 0.262 in².
600S200-54. A 6 in stud or joist with 2 in flanges and 5/8 in lips, 54 mil (design thickness 0.0566 in), usually 50 ksi. The wider flange raises its weak-axis stiffness. Its area is 0.613 in².
800T125-43. An 8 in track: 8.00 in between the flanges inside, so it takes 800S studs or joists. It has 1-1/4 in flanges with no lips, 43 mil (design thickness 0.0451 in), usually 33 ksi. Its outside depth is 8.00 + 2 × 0.0451 = 8.09 in.
Section properties of a 600S162-54#
The 600S162-54 is the stud ColdCalc opens with. These are its gross and effective properties, computed from the designation with rounded corners:
| Area, A | 0.556 | in² |
| Weight | 1.89 | lb/ft |
| Ix | 2.860 | in⁴ |
| Sx | 0.953 | in³ |
| rx | 2.267 | in |
| Iy | 0.180 | in⁴ |
| ry | 0.570 | in |
| J | 0.594 | ×10⁻³ in⁴ |
| Cw | 1.270 | in⁶ |
| xo | -1.043 | in |
| Sxe (effective) | 0.928 | in³ |
A finite strip analysis of the same section in compression gives local buckling at 7.81 kip against a squash load of 27.82 kip: the web buckles locally well before the steel yields, which is normal for cold-formed sections and is why AISI S100 spends so much of its text on buckling. With its compression flange braced, its allowable moment is 25.3 kip·in (ASD). The section page has its buckling loads, available strengths as a column at several heights, and links to check it as a stud, joist or column.
Gauge vs mils#
Older drawings and many conversations still describe framing by gauge: "16 gauge studs". Gauge is a number from sheet-metal practice that falls as the steel gets thicker, and it is not a thickness. Different gauge tables give different thicknesses for the same number, and a gauge says nothing about whether it means the minimum or a nominal thickness, or whether the coating is included.
The trade correspondences are approximate:
| Mils | Gauge, as commonly quoted |
|---|---|
| 33 | 20 |
| 43 | 18 |
| 54 | 16 |
| 68 | 14 |
| 97 | 12 |
Because the match is loose, mils are what a designer should specify. A mil value is a minimum thickness you can measure on site and check against §B7.1, and it fixes the design thickness without ambiguity. If a drawing or a quote gives only a gauge, ask for the mils.
Where to go next#
- The cold-formed steel design guide explains how studs, joists, columns and purlins are checked to AISI S100-24.
- The wall stud design example works through a 600S162-54 stud under axial load and wind, check by check.
- Every SSMA stud and track has its own page under /sections, and the glossary defines every symbol.
What does 600S162-54 mean?
600S162-54 is an SSMA designation for a cold-formed steel stud or joist: 600 is the depth, 6.00 in; S means a C-section with lipped flanges (stud or joist); 162 is the flange width, 1.625 in (1-5/8 in); 54 is the minimum base steel thickness in mils, 0.054 in. Its design thickness is 0.0566 in.
What is the difference between S and T in a stud designation?
S is a stud or joist: a C-section with a lip on each flange, and its depth is measured outside to outside. T is a track: a C-section without lips, used at the top and bottom of walls and as joist rims, and its depth is the inside dimension, so a 600T track fits around a 600S stud.
What thickness is 54 mil steel?
54 mil is a minimum uncoated thickness of 0.054 in. The design thickness used in calculations is 0.0566 in, because AISI S100-24 Section B7.1 allows the delivered thickness to be as low as 95 percent of the design thickness.
Is 54 mil the same as 16 gauge?
54 mil is commonly called 16 gauge, but the match is approximate: gauge numbers are not thicknesses and different gauge tables disagree. Specify the thickness in mils, which is an exact minimum thickness.
What yield strength are cold-formed steel studs?
The designation does not say. Studs and joists are usually ASTM A1003 Grade 33 (33 ksi) below 54 mil and Grade 50 (50 ksi) at 54 mil and heavier, but this varies by manufacturer, so the grade should be specified on the drawings.
How is the inside bend radius of an SSMA stud found?
ColdCalc uses the larger of 3/32 in minus half the design thickness and 1.5 times the design thickness. For 43 mil and thinner the first term governs; for 54 mil and thicker the 1.5t term governs. For a 54 mil section the inside radius is 0.0849 in.