MethodsIntermediate11 min read

The Direct Strength Method in AISI S100-24, with a worked example

The S100-24 Direct Strength Method step by step: elastic buckling loads, slenderness, the new rational strength equations, and a full column example with every number shown.

By ColdCalc Engineering
In short
  • The Direct Strength Method (DSM) predicts a cold-formed steel member's strength from the elastic buckling loads of the whole cross-section (local Pcrℓ, distortional Pcrd, global Pcre, or the matching moments), instead of reducing each flat plate to an effective width.
  • AISI S100-24 rewrote every DSM strength curve in one rational form. For columns, local buckling is Pnℓ = 1.2Pne(1 + 0.10λℓ²)/(1 + 0.55λℓ²) ≤ Pne (Eq. E3.2-1). For columns it gives practically the same strengths as the S100-16 curves. For beams, the new curves rise toward the plastic moment Mp and are capped at My3.
  • A 600S162-54 stud as a short column has Pnℓ = 15.30 kip and Pnd = 15.02 kip, so §E4 governs. At 10 ft with bridging at 48 in, global buckling lowers Pne to 16.70 kip, and local buckling governs at 11.18 kip.
  • Inside the limits of Table B4.1-1, DSM uses Ω = 1.80, φ = 0.85 for columns and Ω = 1.67, φ = 0.90 for beams. Outside them, §B4.2 still permits DSM with the rational engineering analysis factors Ω = 2.00, φ = 0.80.

The Direct Strength Method needs an elastic buckling analysis of the cross-section, but in exchange it works for almost any shape. This article sets out the S100-24 equations for columns and beams, then works a real stud through every step, with each number computed by the ColdCalc engine.

What the Direct Strength Method is, and why it exists#

A cold-formed section is a chain of thin flat plates joined at corners. Under load the plates buckle locally well before the steel yields (the buckling modes article shows this for real studs). The traditional answer is the Effective Width Method (EWM) of Appendix 1. It treats each plate on its own, removes the part that buckles, and computes the strength of what is left.

That works for simple shapes, but the interaction between web, flange and lip is only approximated, distortional buckling (where the corners move) is not an element-level mode at all, and complex stiffeners fall outside the element rules.

DSM, developed by Schafer and Peköz and first adopted by AISI in 2004, takes a different route. It analyses the whole cross-section for elastic buckling and reads the strength from a curve calibrated on tests:

  1. Find the elastic buckling loads of the section: global, local and distortional.
  2. Compute a slenderness for each mode: the square root of the yield (or global) strength over the buckling load.
  3. Read the nominal strength from that mode's strength curve. The least strength governs.

The Specification defines it as a method "that provides predictions of member strengths without the use of effective widths" (§A1.3), and §B4 makes the two methods "equally acceptable". The EWM vs DSM article compares their answers.

The inputs#

MemberYieldGlobalLocalDistortional
ColumnPy = AgFyPcre → Pne (§E2)PcrℓPcrd
BeamMy = SfFy, Mp = ZfFyMcre → Mne (§F2.2)McrℓMcrd

All of them are elastic properties of the gross section. Appendix 2 §2.1 converts between stress and force with the gross area (Pcr = AgFcr, Eq. 2.1-1) and between stress and moment with the gross section modulus to the compression fiber (Mcr = SfcFcr, Eq. 2.1-2). No effective section is computed anywhere.

The column equations in S100-24#

Global buckling and yielding: §E2

The global strength is the same for both methods. With λc = √(Fy/Fcre) (Eq. E2-4):

Fn = 0.658λc²Fy for λc ≤ 1.5; Fn = (0.877/λc²)Fy for λc > 1.5
Eq. E2-2, E2-3
Pne = AgFn
Eq. E2-1

Fcre is the flexural, torsional or flexural-torsional buckling stress at the member's effective lengths, from Appendix 2 §2.3.1 or a numerical analysis.

Local buckling: §E3.2

Pnℓ = 1.2Pne(1 + 0.10λℓ²)/(1 + 0.55λℓ²) ≤ Pne, with λℓ = √(Pne/Pcrℓ)
Eq. E3.2-1, E3.2-2

The local slenderness is measured against Pne, not Py. That is how DSM captures local–global interaction: a column that is already near its global buckling load has less stress available to buckle its plates. The curve reaches the cap Pne for λℓ up to about 0.68 (where 1.2(1 + 0.10λ²) = 1 + 0.55λ²). Beyond that, local buckling reduces the strength. The equation applies for λℓ ≤ 5. Members with holes also check Eq. E3.2-3, which caps the strength at the net-section yield load Pynet = AnetFy.

Distortional buckling: §E4

Pnd = 1.2Py(1 + 0.05λd²)/(1 + 0.67λd²) ≤ Py, with λd = √(Py/Pcrd)
Eq. E4-1, E4-2

Distortional slenderness is measured against the squash load Py = AgFy (Eq. E4-3), so the Specification assumes distortional buckling does not interact with global buckling. The cap applies up to λd of about 0.57. Section E4 covers I-, Z-, C-, hat and other open sections with edge-stiffened flanges, and any section with intermediate stiffeners, again for λd ≤ 5.

What changed from S100-16

S100-16 used power-law curves of the Winter type, for example Pnℓ = (1 − 0.15x)x·Pne with x = (Pcrℓ/Pne)0.4, for λℓ > 0.776. The 2024 Commentary credits the new rational form to Glauz (2023), "providing equivalent strength predictions and consistent with the equation forms used for the DSM flexural strength curves". The plots bear that out. The solid S100-24 curve and the dashed S100-16 curve lie almost on top of each other for local buckling:

0.00.20.40.60.81.001234slenderness λℓS100-24S100-16600S162-54: λ = 1.89, 0.55
Direct Strength Method local buckling strength of columns: Pnℓ/Pne against λℓ = √(Pne/Pcrℓ). Solid: AISI S100-24 Eq. E3.2-1. Dashed: the AISI S100-16 equation it replaced. The dot is the 600S162-54 as a short column (Pne = Py).

The distortional curves differ a little more:

0.00.20.40.60.81.001234slenderness λdS100-24S100-16600S162-54: λ = 1.48, 0.54
Direct Strength Method distortional buckling strength of columns: Pnd/Py against λd = √(Py/Pcrd). Solid: AISI S100-24 Eq. E4-1. Dashed: the AISI S100-16 equation it replaced. The dot is the 600S162-54 as a short column (Pne = Py).

One real difference is at high slenderness. The old curves fall toward zero, but the new ones level off: as λℓ grows, Eq. E3.2-1 tends to 1.2 × 0.10/0.55 ≈ 0.22Pne. The Commentary explains the λ ≤ 5 limit by the uncertainty of predictions at high slenderness. Beyond it, it offers rational limits such as Pnℓ ≤ Pne/λℓ0.8 (Eq. C-E3.2-1).

The beam equations in S100-24#

The beam provisions changed more: the new curves include inelastic reserve, the strength beyond first yield.

Global: §F2.2

Mne = Mp(1 − 0.25Mp/Mcre) for Mcre > 0.5Mp; Mne = Mcre otherwise; Mp = ZfFy
Eq. F2.2-1 to F2.2-3

A fully braced beam (Mcre → ∞) has Mne = Mp. If the yield stress includes the cold work of forming, Mne may not exceed My.

Local: §F3.2

Mnℓ = ksM̄ne(1 + 0.10αsλℓ²)/(1 + 0.55βsλℓ²) ≤ My3, with λℓ = √(M̄ne/Mcrℓ)
Eq. F3.2-1, F3.2-2
ks = Mp/My; βs = 2yc/d ≥ 0.4; My3 = Mp − (Mp − My)/9
Eq. F3.2-3 to F3.2-5

What each term does:

  • M̄ne is the lesser of Mne and My. Multiplied by the shape factor ks, it gives Mp for a braced beam, so the curve starts at the plastic moment.
  • αs is 1 for sections with corners at the extreme compression fiber and 0 otherwise. Corners don't translate in local buckling, so they hold the compression fiber in place. With αs = 0, the strength drops faster as slenderness rises. The Commentary relates this to open sections with free edges in compression, and allows αs between 0 and 1 by rational analysis.
  • βs is 1 for sections symmetric about the bending axis. It is below 1 when the section first yields in tension, where post-buckling redistribution helps, and above 1 when it first yields in compression.
  • My3 is the "member moment at strain limit". For a solid rectangle, Mp − (Mp − My)/9 is exactly the moment when the extreme fiber strain reaches three times the yield strain. It caps the inelastic reserve.

The Commentary says the form was developed by Glauz and Schafer (2022) "to capture strength prediction throughout the entire range of slenderness including inelastic reserve strength (Mn > My)", and that it was then adopted for all DSM curves.

Distortional: §F4

Mnd = Mp(1 + 0.07αsλd²)/(1 + 0.60βsλd²) ≤ My3, with λd = √(My/Mcrd)
Eq. F4-1, F4-2

Here αs = 1 when one or more corners at the extreme compression fiber do not translate in the distortional mode. For a lipped C, that is the web–flange corner the flange rotates about. βs is defined as for local buckling (Eq. F4-3).

Worked example: a 600S162-54 column#

The 600S162-54 is a 6 in deep stud with 1-5/8 in flanges, 54 mil (design thickness 0.0566 in), Fy = 50 ksi. Its gross area is 0.556 in², so the squash load is Py = 27.82 kip.

The finite strip analysis gives the two cross-section buckling loads:

  • Local: Pcrℓ = 7.81 kip, at a half-wavelength of 4.5 in. That is under a third of Py: the plates buckle at a low stress.
  • Distortional: Pcrd = 12.72 kip, at 16.4 in. This section's signature curve has no distinct distortional minimum, so the mode was identified by its modal participation (cFSM).

We check two cases: a short column, where global buckling can't occur, and a 10 ft stud with pinned ends and bridging at 48 in that braces the weak axis and twisting.

  1. Global strength. Short column: Pne = Py. Braced column: with KxLx = 120 in and KyLy = KtLt = 48 in, Appendix 2 gives flexural buckling about the y-axis at Pcre = 22.81 kip. So λc = 1.104, Fn = 30.01 ksi and Pne = 16.70 kip.
  2. Local strength. Short: λℓ = √(27.82/7.81) = 1.887, so Pnℓ = 15.30 kip, which is 55 % of Pne. Braced: λℓ = 1.462 and Pnℓ = 11.18 kip. The slenderness fell because Pne fell, so a larger share of Pne survives (67 %), but of a smaller number.
  3. Distortional strength. λd = √(Py/Pcrd) = 1.479 and Pnd = 15.02 kip, the same for both cases, because §E4 does not depend on the member length unless sheathing or closely spaced braces raise Pcrd.
  4. Governing strength. Short: §E4, Pn = 15.02 kip. Braced: §E3.2, Pn = 11.18 kip, so Pn/Ωc = 6.21 kip (ASD) or φcPn = 9.50 kip (LRFD).
StepShortBraced, 10 ftUnitReference
Global buckling load Pcre—22.81kipApp. 2 §2.3.1
Global buckling stress Fcre—41.0ksiEq. 2.1-1
Global slenderness λc0.0001.104Eq. E2-4
Compressive stress Fn50.0030.01ksiEq. E2-2
Global strength Pne = AgFn27.8216.70kipEq. E2-1
Local slenderness λℓ = √(Pne/Pcrℓ)1.8871.462Eq. E3.2-2
Local strength Pnℓ15.3011.18kipEq. E3.2-1
Distortional slenderness λd = √(Py/Pcrd)1.4791.479Eq. E4-2
Distortional strength Pnd15.0215.02kipEq. E4-1
Nominal strength Pn (least)15.0211.18kip§E1
ASD Pn/Ωc8.356.21kipΩ = 1.80
LRFD φcPn12.779.50kipφ = 0.85
The 600S162-54 column, AISI S100-24 Direct Strength Method. Short column: no global buckling, so Pne = Py. Braced column: 10 ft tall, pinned ends, bridging at 48 in bracing the weak axis and twist (KxLx = 120 in, KyLy = KtLt = 48 in). Py = 27.82 kip, Pcrℓ and Pcrd from the finite strip analysis. The governing value is in bold. Computed by ColdCalc.

Three things stand out. First, as a short column the 600S162-54 is governed by distortional buckling, though only just: local and distortional strengths are within a few percent. Second, even with bridging at 48 in, global buckling between the bridging lines cuts Pne to 60 % of Py. Through local–global interaction, that pulls the local strength well below the short-column value. Third, the braced result equals the 10 ft row of the 600S162-54 section page (11.18 kip nominal), which uses the same assumptions. The S100-16 curves would have given Pnℓ = 15.22 kip and Pnd = 14.68 kip for the short column, close to the S100-24 values.

The same stud as a joist braced against lateral-torsional buckling shows the beam equations. Its shape factor is ks = 1.196, αs = βs = 1, and distortional buckling governs at Mnd = 42.22 kip·in. That is below My = 47.67 kip·in, so this stud gets no inelastic reserve.

Yield moment My = SfFy47.67kip·inEq. F2.1-2
Plastic moment Mp = ZfFy57.03kip·inEq. F2.2-3
Global strength Mne (braced: Mp)57.03kip·inEq. F2.2-1
Shape factor ks = Mp/My1.196Eq. F3.2-3
αs (corners at the compression fiber)1§F3.2, §F4
βs = 2yc/d ≥ 0.41.00Eq. F3.2-4
Strain-limit moment My355.99kip·inEq. F3.2-5
Local slenderness λℓ = √(M̄ne/Mcrℓ)0.810Eq. F3.2-2
Local strength Mnℓ44.67kip·inEq. F3.2-1
Distortional slenderness λd = √(My/Mcrd)0.833Eq. F4-2
Distortional strength Mnd42.22kip·inEq. F4-1
ASD Mn/Ωb25.28kip·inΩ = 1.67
LRFD φbMn38.00kip·inφ = 0.90
The 600S162-54 in strong-axis bending with the compression flange braced (Mcre → ∞), AISI S100-24 Sections F2.2, F3.2 and F4, with Mcrℓ and Mcrd from the finite strip analysis. Distortional buckling (§F4) governs. Computed by ColdCalc.

Safety and resistance factors#

DSM uses the same factors as the EWM for the same limit state:

Limit stateΩ (ASD)φ (LRFD)φ (LSD, Canada)
Compression, §E2, §E3, §E41.800.850.80
Flexure, §F2, §F3, §F41.670.900.90

The Commentary reports φ = 0.84 calculated for columns and 0.90 for beams at a target reliability βo = 2.5. These factors apply only within Table B4.1-1.

Where the finite strip results come from#

Appendix 2 lets you find Pcrℓ, Pcrd and Pcre numerically (§2.2: "any numerical elastic buckling solution that includes the relevant mechanics") or with the analytical solutions of §2.3 (§2.3.2 local, §2.3.3 distortional), or any combination. The usual numerical tool is the finite strip method. It produces the signature curve, whose minima are the local and distortional buckling loads. CUFSM, Schafer's free program, computes these elastic buckling values for you to take into the DSM equations, and CFS (RSG Software) includes a finite strip analysis too. ColdCalc runs a finite strip analysis for every section and labels each minimum by its modal participation. The finite strip article explains the method and how to read the results.

The element formulas of §2.3.2 ignore the restraint each plate gets from its neighbours, so they can be very conservative for local buckling. The distortional solutions of §2.3.3 include a rotational restraint kφ from sheathing or deck.

Limits of applicability: §B4#

The DSM factors may be used only for members within Table B4.1-1. Its DSM column applies to §E3.2, §E4, §F3.2 and §F4 (note c of the table). The main limits, against the EWM's:

CriterionEWMDSM
Stiffened element, w/t≤ 500≤ 500
Edge-stiffened element, b/t≤ 90 (Is ≥ Ia), ≤ 60 (Is < Ia)≤ 160
Unstiffened element, d/t≤ 60≤ 60
Web in bending, h/t≤ 300≤ 300
Inside bend radius, R/t≤ 10≤ 20
Simple lip, do/bo≤ 0.7≤ 0.7
Edge stiffenerSimple lip onlySimple and complex
Intermediate stiffeners in the web, nw04
Nominal yield stress Fy≤ 80 ksi≤ 95 ksi

Members outside these limits fall under §A1.2 (tests or rational engineering analysis), but §B4.2 makes an exception for DSM. You may still use it with (a) the rational engineering analysis factors of §A1.2.6(c), Ω = 2.00 and φ = 0.80 (0.75 LSD), or (b) the Chapter E–H factors, if a §K2 analysis of at least three tests supports them. Section A1.2.7 adds that these factors may never be less conservative than the limit state's own. ColdCalc checks every section against Table B4.1-1 and applies the §A1.2.6(c) factors automatically when a DSM design falls outside it.

What is the Direct Strength Method in cold-formed steel design?

The Direct Strength Method (DSM) predicts the strength of a cold-formed steel member from the elastic buckling loads of its whole cross-section: local, distortional and global. Each buckling load gives a slenderness, and a strength curve calibrated on tests turns that slenderness into a nominal strength. It needs no effective widths. In AISI S100-24 it is in Sections E2, E3.2 and E4 for columns and F2.2, F3.2 and F4 for beams.

What changed in the DSM equations in AISI S100-24?

S100-24 replaced the power-law DSM curves with one rational form. For columns, Pnl = 1.2Pne(1 + 0.10 lambda^2)/(1 + 0.55 lambda^2) <= Pne and Pnd = 1.2Py(1 + 0.05 lambda^2)/(1 + 0.67 lambda^2) <= Py, which give practically the same strengths as S100-16. For beams, the global strength is based on the plastic moment Mp, and the local and distortional curves include inelastic reserve through ks, the alpha-s and beta-s factors, and the cap My3 = Mp - (Mp - My)/9.

How do I get Pcrl and Pcrd for the Direct Strength Method?

Run an elastic buckling analysis of the cross-section, usually the finite strip method (for example CUFSM or ColdCalc), and read the local and distortional minima of the signature curve. AISI S100-24 Appendix 2 Section 2.2 permits any numerical method with the relevant mechanics, and Section 2.3 gives analytical formulas, which tend to be conservative for local buckling.

What are the safety and resistance factors for the Direct Strength Method?

For members within Table B4.1-1 of AISI S100-24, DSM uses the Chapter E and F factors: Omega = 1.80 and phi = 0.85 (LRFD) for compression, Omega = 1.67 and phi = 0.90 for flexure. Members outside those limits may still be designed by DSM with Omega = 2.00 and phi = 0.80 (Section B4.2(a)).

Does local or distortional buckling govern a cold-formed steel stud?

It depends on the section and the bracing. For a 600S162-54 as a short column, the S100-24 local and distortional strengths are within a few percent and distortional governs. As a 10 ft stud braced at 48 in, global buckling reduces Pne, and local buckling interacting with global buckling governs.

Numbers in this article are computed by the ColdCalc engine when the page is built, so they match what the calculator gives today. AISI S100-24 is the governing text; ColdCalc is a design aid, and its results should be reviewed by the engineer responsible for the design.