Effective Width Method vs Direct Strength Method: when they differ, and why
How the two AISI S100 methods model local and distortional buckling, where their answers diverge for studs and tracks, and how to choose between them.
- Both methods use the same global strength (§E2, §F2) and differ only in how they account for local buckling. The Effective Width Method (EWM, §E3.1 and §F3.1 with Appendix 1) removes the buckled part of each flat element using Winter's equation. The Direct Strength Method (DSM, §E3.2 and §F3.2) applies one strength curve to the elastic local buckling load of the whole section.
- Distortional buckling (§E4, §F4) is checked the same way whichever method you choose. For lipped studs in bending, where distortional buckling usually governs, the two methods give nearly identical answers: the 600S162-54 has Mn = 42.2 kip·in by EWM and 42.2 kip·in by DSM.
- Where local buckling governs, the methods differ by roughly 5 to 20 %, and not always in the same direction. A braced 600T200-54 track in bending is 13 % weaker by DSM. As a short column, the same track is 11 % stronger by DSM.
- AISI S100-24 §B4: "Either the Effective Width Method or the Direct Strength Method shall be equally acceptable", within the limits of Table B4.1-1. Outside those limits, §B4.2 still permits DSM with Ω = 2.00, φ = 0.80. Any other method needs tests or rational engineering analysis (§A1.2).
Every cold-formed steel member check has to answer one question: how much strength do the thin walls lose when they buckle locally? AISI S100-24 gives two answers, and lets you pick either. This article explains how each one works, shows where their numbers agree and where they don't, and explains why from the Specification. Every number comes from the ColdCalc engine.
The same problem, two methods#
A cold-formed section's flat walls buckle locally at stresses well below yield, then keep carrying load after they buckle (how the three buckling modes differ). Both methods turn that behaviour into a design strength, and both share the rest of the member check:
| Effective Width Method | Direct Strength Method | |
|---|---|---|
| Global buckling and yielding | §E2, §F2.1 | §E2, §F2.2 |
| Local buckling | §E3.1, §F3.1 with Appendix 1 | §E3.2, §F3.2 |
| Distortional buckling | §E4, §F4 | §E4, §F4 |
| What you compute | Effective width of each element, then effective area Ae or section modulus Se | Elastic buckling loads Pcrℓ, Pcrd (or Mcrℓ, Mcrd) of the whole section |
| Factors within Table B4.1-1 | Ω = 1.80, φ = 0.85 (compression); Ω = 1.67, φ = 0.90 (flexure) | Same |
The Commentary to §E1 puts it simply: "In considering column yielding and global buckling, the DSM is essentially the same as the EWM. However, the approach of the two methods in predicting the strength due to local buckling is different."
How the Effective Width Method works#
The EWM looks at one flat element at a time. Each element is a plate supported along one or both long edges. Appendix 1 §1.1 gives its elastic buckling stress and then its effective width:
This is Winter's effective width equation. It replaces the buckled plate, whose stress is high at the supported edges and low in the middle, by a narrower plate at the full edge stress. The plate buckling coefficient k depends on how the element is supported:
- Stiffened elements, supported by a web on each long edge, such as the web of a stud between its flanges: k = 4 (§1.1).
- Unstiffened elements with one free edge, such as the flanges of a track: k = 0.43 (§1.2.1), so they buckle at about a ninth of the stress of an equally slender stiffened element.
- Flanges with a simple lip (§1.3): k comes from Table 1.3-1 and depends on how stiff the lip is, through RI = Is/Ia ≤ 1. A lip shorter than adequate reduces both the flange's effective width and the lip's own.
- Webs under a stress gradient (§1.1.2): k = 4 + 2(1 + ψ)³ + 2(1 + ψ), with ψ = |f2/f1|. The effective width is split into b1 and b2 at the two ends of the compression zone.
The stress f is where the method's two uses part ways. In a column, every element is at the same stress, f = Fn from §E2, and the strength is Pn = AeFn ≤ Pne (Eq. E3.1-1). In a beam, the stresses f1 and f2 in the web are "calculated on the basis of effective section" (§1.1.2). But the effective section depends on the web's effective widths, so the calculation has to iterate:
- Start with the gross section's neutral axis, and set the compression fiber stress to Fn (Fy for a braced beam).
- Compute the stress in each element from that neutral axis, then its effective width: flanges and lips by §1.2 or §1.3, the web's b1 and b2 by §1.1.2.
- Remove the ineffective parts and find the new neutral axis. It moves toward the tension flange, because only compression elements lose area.
- Repeat until the neutral axis stops moving. The result gives Sec at the compression fiber and Set at the tension fiber, and Mn = SecFn ≤ SetFy (Eq. F3.1-1).
For a braced 600S162-54, this gives an effective section modulus Sxe = 0.928 in³ against the gross Sx = 0.953 in³, or 97 % of it. The lipped compression flange is almost fully effective, and only the upper part of the web loses some width. For the 600T200-54 track, whose compression flange has a free edge, Sxe = 0.703 in³ against Sx = 0.996 in³, only 71 %.
The EWM is capped at the yield moment My unless you use the inelastic reserve provisions of §F2.1.1, which allow up to 1.25SeFy under conditions on bracing, web slenderness and shear.
How the Direct Strength Method works#
DSM skips the elements. A finite strip analysis gives the elastic local buckling moment Mcrℓ of the whole cross-section, including the restraint that each plate gives its neighbours. Then one curve turns the slenderness λℓ = √(M̄ne/Mcrℓ) into a strength:
The column form is Pnℓ = 1.2Pne(1 + 0.10λℓ²)/(1 + 0.55λℓ²) ≤ Pne (Eq. E3.2-1). In S100-24 the beam curve starts from the plastic moment, ksM̄ne = Mp for a braced beam, so DSM includes inelastic reserve without a separate check. The Direct Strength Method article explains every term and works a column example.
Where they agree: lipped studs in bending#
Here are the bending strengths of four SSMA studs and two tracks with the compression flange braced, by each method:
| Section | EWM Mn | DSM Mn | DSM / EWM | DSM governs by |
|---|---|---|---|---|
| 362S162-33 | 9.0 | 9.0 | 1.00 | Distortional (F4) |
| 600S162-33 | 16.7 | 16.0 | 0.96 | Local (F3.2) |
| 600S162-54 | 42.2 | 42.2 | 1.00 | Distortional (F4) |
| 800S200-54 | 66.8 | 66.8 | 1.00 | Distortional (F4) |
| 600T200-54 | 35.1 | 30.6 | 0.87 | Local (F3.2) |
| 362T125-33 | 5.6 | 5.3 | 0.94 | Local (F3.2) |
kip·in
Three of the four lipped studs agree to the first decimal. The reason is in the Specification, not in the local buckling equations. Section F1 makes the available strength "the smallest of the values calculated in accordance with Sections F2 to F4". Section F4 applies to "I-, Z-, C-, and other open cross-section members that employ compression flanges with edge stiffeners", whichever method you use for §F3. Its only exception covers distortional modes of intermediate stiffeners designed by §F3.1 with Appendix 1 §1.4, and the text adds that "distortional buckling modes involving edge-stiffened flanges are not part of this exception". Table B4.1-1 confirms it: its DSM column (note c) covers §E4 and §F4, so even an EWM design uses DSM equations and limits for distortional buckling.
So when distortional buckling governs, both methods run the same equation on the same Mcrd, and they give the same answer. Separating the limit states shows what is underneath:
| Section | EWM local (F3.1) | DSM local (F3.2) | Distortional (F4) |
|---|---|---|---|
| 362S162-33 | 9.6 | 9.3 | 9.0 |
| 600S162-33 | 19.1 | 16.0 | 16.7 |
| 600S162-54 | 46.4 | 44.7 | 42.2 |
| 800S200-54 | 75.1 | 67.2 | 66.8 |
| 600T200-54 | 35.1 | 30.6 | — |
| 362T125-33 | 5.6 | 5.3 | — |
The local buckling strengths do differ. For the 800S200-54, DSM's §F3.2 is 11 % below EWM's §F3.1, but §F4 is lower than both, so the difference never reaches the result. In the 600S162-33 the DSM local strength drops just below the distortional one and governs, so the two methods part by a few percent.
Where they differ: when local buckling governs#
Tracks have no lips, so §F4 doesn't apply to them and local buckling decides. For the 600T200-54 in bending, DSM is 13 % lower; for the 362T125-33, 6 %. The two methods model the track differently:
- EWM reduces the compression flange hard. It has a free edge and k = 0.43. The web is under a stress gradient with a much higher k, and it stays nearly fully effective. The effective section keeps 71 % of Sx.
- DSM computes one slenderness for the whole section, λℓ = 1.61, controlled by the flange's buckling, and applies the reduction to the whole section. The resulting Mnℓ is 62 % of My.
In compression, the picture changes. Here every element is at the same stress, and the EWM reduces each one separately with no credit for interaction. The two methods are compared at the same §E2 global strength:
| Section | Short, EWM | Short, DSM | 10 ft, EWM | 10 ft, DSM |
|---|---|---|---|---|
| 362S162-33 | 6.43E3.1 | 5.56E3.2 | 4.47E3.1 | 4.10E3.2 |
| 600S162-33 | 5.64E4 | 4.98E3.2 | 5.19E3.1 | 4.09E3.2 |
| 600S162-54 | 15.02E4 | 15.02E4 | 11.97E3.1 | 11.18E3.2 |
| 800S200-54 | 15.67E4 | 15.67E4 | 15.67E4 | 12.97E3.2 |
| 600T200-54 | 12.03E3.1 | 13.38E3.2 | 9.05E3.1 | 10.04E3.2 |
| 362T125-33 | 3.59E3.1 | 3.91E3.2 | 2.21E3.1 | 2.38E3.2 |
For the lipped studs, DSM gives the lower local strength: 13 % lower for the 362S162-33 as a short column and 21 % lower for the 600S162-33 at 10 ft. Where §E4 governs both, as for the short 600S162-54, the two results are equal. For the tracks it reverses: DSM is 11 % higher for the short 600T200-54. A track's web in uniform compression is about as slender as its unstiffened flanges, so the EWM reduces every element of the section.
Neither method is uniformly conservative. They are separate calibrations against tests: the Commentary reports φ = 0.84 calculated for the DSM column provisions (0.85 adopted), and refers to its 1991 edition for the EWM's calibration.
When to use each#
Use DSM when:
- The shape is outside the EWM's element rules: complex edge stiffeners (Table B4.1-1 allows "Simple lip only" for the EWM), intermediate stiffeners in the web (nw = 0 for the EWM, up to 4 for DSM), R/t between 10 and 20, or Fy between 80 and 95 ksi.
- The section is outside Table B4.1-1 altogether. Section B4.2 sends such members to §A1.2 (tests or rational engineering analysis), "with the exception that members are permitted to be designed using the Direct Strength Method" with the §A1.2.6(c) factors, Ω = 2.00 and φ = 0.80, or with a §K2 test-based check.
- You want inelastic reserve in bending without the §F2.1.1 conditions, or one consistent method for local and distortional buckling.
Use the EWM when:
- You need effective section properties themselves, such as Ixe or Sxe. For deflection, both methods work: §L1 uses the Appendix 1 effective moment of inertia, and §L2 scales the gross Ig by Md/M from the DSM equations.
- The member has holes that fit Appendix 1 §1.1.1 and its limits, or shear lag limits the flange width (§B4.3, which is written in terms of effective design widths). The DSM route for holes needs buckling values that include the holes, from Appendix 2.
- You are checking older calculations or a manufacturer's load tables computed with effective widths.
Holes and stiffeners are possible either way, through different routes. With DSM, holes enter through the elastic buckling loads (Pcrℓ, Pcrd, Pcre with holes) and the net-section caps Pynet and My3net (Eqs. E3.2-3, F3.2-6). With the EWM, holes enter through the element provisions of Appendix 1.
What S100-24 says about choosing#
The rule is in §B4: "Either the Effective Width Method or the Direct Strength Method shall be equally acceptable." Neither method is the default. You may use either one for a member, as long as it meets Table B4.1-1, and the Chapter E–H factors then apply. The table has separate columns: note b says the EWM limits apply to §E3.1, §F3.1 and Appendix 1, and note c says the DSM limits apply to §E3.2, §E4, §F3.2 and §F4.
Section B3.3 adds that members outside §B4 "are permitted to be designed in accordance with Section A1.2". Under §A1.2.6(c), rational engineering analysis uses Ω = 2.00 and φ = 0.80 (0.75 LSD) for members. Section A1.2.7 adds that, for a limit state the Specification already covers, those factors may not be less conservative than the limit state's own. Section B4.2 is the one place where the choice of method matters: outside the table, it names DSM, with those factors, as the method still permitted.
Switching methods in ColdCalc#
In the calculator, Design settings has a Strength approach choice, Direct strength (DSM) or Effective width (EWM), and an Elastic buckling choice, Finite strip or Analytical. DSM with finite strip buckling is the default. Changing the approach reruns every member check. Each limit state then lists its intermediate values with equation numbers: Ae, Sec and Set for the EWM, or the buckling loads and slenderness for DSM. The §F4 and §E4 distortional checks stay in both, as the Specification requires. Each section page lists Sxe and both bending strengths side by side.
Which is more conservative, the effective width method or the direct strength method?
Neither, consistently. For lipped C-studs in bending, distortional buckling (AISI S100-24 Section F4) usually governs both methods, so they agree. Where local buckling governs, the SSMA sections compared in this article show DSM lower for tracks in strong-axis bending and for lipped studs in compression, but higher for tracks in compression, by about 5 to 20 percent.
Can I use either EWM or DSM under AISI S100-24?
Yes. Section B4 states that either the Effective Width Method or the Direct Strength Method shall be equally acceptable. To use the safety and resistance factors of Chapters E through H, the member must meet the limits of Table B4.1-1 for the method used. Outside those limits, DSM may still be used with the rational engineering analysis factors (Omega = 2.00, phi = 0.80).
Does the effective width method check distortional buckling?
Yes. Distortional buckling is checked by Sections E4 and F4 for any member with edge-stiffened flanges, whichever method is used for local buckling. The only exception is distortional modes involving only intermediate stiffeners, when the member is designed by the Effective Width Method with Appendix 1 Section 1.4.
What is the effective section modulus Sxe?
Sxe is the section modulus of the effective section about the strong axis: the gross section with the ineffective parts of each compression element removed, computed with the Appendix 1 effective widths at the compression fiber stress (Fy for a braced beam). The Effective Width Method's local buckling moment is Mn = Sec Fn. For a 600S162-54 it is about 97 percent of the gross Sx; for a 600T200-54 track, about 70 percent.
Why can DSM give a lower bending strength than EWM for a cold-formed steel track?
A track's compression flange has a free edge, so its local buckling moment is low. The Direct Strength Method applies the resulting slenderness to the whole section, while the Effective Width Method reduces mainly the flange and keeps the web nearly fully effective. With no lip, the distortional check that governs lipped studs by both methods does not apply, so the local buckling difference shows in the result.