1000S350-54 stud properties and strength

SSMA 10 in stud or joist, 3-1/2 in flange, 54 mil (0.0566 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1000S350-54 has an area of 1.052 in² and weighs 3.58 lb/ft. Its strong-axis moment of inertia is 16.220 in⁴ gross and 13.308 in⁴ effective at yield, and its effective section modulus is 2.330 in³. With the flange braced, its allowable moment is 64.8 kip·in (ASD), governed by local buckling (§F3).

10″3-1/2″1″ lipt = 0.0566″

Dimensions

Depth10in
Flange width3-1/2in
Lip length1in
Design thickness0.0566in
Minimum thickness0.0538in
Inside bend radius0.0849in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.052in²
Weight3.58lb/ft
Ix16.220in⁴
Sx3.244in³
rx3.927in
Iy1.768in⁴
Sy0.710in³
ry1.297in

Torsion and effective section

J1.123×10⁻³ in⁴
Cw35.720in⁶
xo-2.543in
ro4.855in
β0.726
Ixe at yield13.308in⁴
Sxe2.330in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)108.2764.8397.44§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)111.3766.69100.24§F4 · kip·in
Shear, web without holes4.362.613.93§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)17.859.9215.17§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)17.849.9115.16§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)17.839.9015.15§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)17.779.8715.10§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)17.579.7614.94§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)17.209.5514.62§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.10 at 7.6 inDistortional0.30 at 41.6 in
Signature curve of the 1000S350-54 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (M/My)Local0.51 at 5.5 inDistortional0.69 at 40.9 in
Signature curve of the 1000S350-54 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py52.58kip
Pcrℓ at 7.65.15kip
Pcrd at 41.615.94kip
My162.20kip·in
Mcrℓ at 5.581.94kip·in
Mcrd at 40.9112.38kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
5.15 kip at 7.6 in
Distortional
15.94 kip at 41.6 in
Buckled shapes of the 1000S350-54 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1000S350-54 mean?

1000S350-54 is an SSMA designation: 10 in stud or joist, 3-1/2 in flange, 54 mil (0.0566 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0566 in.

What are the section properties of a 1000S350-54 stud?

Area 1.052 in², weight 3.58 lb/ft, Ix 16.220 in⁴, Sx 3.244 in³, rx 3.927 in, Iy 1.768 in⁴, ry 1.297 in, J 1.123 ×10⁻³ in⁴, Cw 35.720 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1000S350-54?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 108.3 kip·in by the Direct Strength Method (governed by §F3.2): 64.8 kip·in allowable (ASD) or 97.4 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1000S350-54?

By finite strip analysis, local buckling in compression occurs at 5.15 kip (half-wavelength 7.6 in) and distortional buckling at 15.94 kip (41.6 in), against a squash load Py of 52.58 kip.

Other 10 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation