1000S200-33 stud properties and strength

SSMA 10 in stud or joist, 2 in flange, 33 mil (0.0346 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1000S200-33 has an area of 0.517 in² and weighs 1.76 lb/ft. Its strong-axis moment of inertia is 7.013 in⁴ gross and 5.735 in⁴ effective at yield, and its effective section modulus is 0.980 in³. With the flange braced, its allowable moment is 16.2 kip·in (ASD), governed by local buckling (§F3).

10″2″0.625″ lipt = 0.0346″

Dimensions

Depth10in
Flange width2in
Lip length0.625in
Design thickness0.0346in
Minimum thickness0.0329in
Inside bend radius0.0765in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.517in²
Weight1.76lb/ft
Ix7.013in⁴
Sx1.403in³
rx3.682in
Iy0.241in⁴
Sy0.153in³
ry0.682in

Torsion and effective section

J0.206×10⁻³ in⁴
Cw4.726in⁶
xo-1.152in
ro3.918in
β0.914
Ixe at yield5.735in⁴
Sxe0.980in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)27.1216.2424.41§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)32.3419.3729.11§F3.1 · kip·in
Shear, web without holes1.100.550.88§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)4.512.503.83§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)4.512.503.83§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)4.512.503.83§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)4.512.503.83§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)4.512.503.83§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)4.512.503.83§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.06 at 7.3 inDistortional (by cFSM)0.14 at 32.0 in
Signature curve of the 1000S200-33 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (M/My)Local0.32 at 5.3 inDistortional0.66 at 24.6 in
Signature curve of the 1000S200-33 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py17.07kip
Pcrℓ at 7.30.99kip
Pcrd at 32.02.41kip
My46.29kip·in
Mcrℓ at 5.314.74kip·in
Mcrd at 24.630.35kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
0.99 kip at 7.3 in
Distortional
2.41 kip at 32.0 in
Buckled shapes of the 1000S200-33 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1000S200-33 mean?

1000S200-33 is an SSMA designation: 10 in stud or joist, 2 in flange, 33 mil (0.0346 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0346 in.

What are the section properties of a 1000S200-33 stud?

Area 0.517 in², weight 1.76 lb/ft, Ix 7.013 in⁴, Sx 1.403 in³, rx 3.682 in, Iy 0.241 in⁴, ry 0.682 in, J 0.206 ×10⁻³ in⁴, Cw 4.726 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1000S200-33?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 27.1 kip·in by the Direct Strength Method (governed by §F3.2): 16.2 kip·in allowable (ASD) or 24.4 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1000S200-33?

By finite strip analysis, local buckling in compression occurs at 0.99 kip (half-wavelength 7.3 in) and distortional buckling at 2.41 kip (32.0 in), against a squash load Py of 17.07 kip.

Other 10 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation