1000S350-43 stud properties and strength

SSMA 10 in stud or joist, 3-1/2 in flange, 43 mil (0.0451 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1000S350-43 has an area of 0.842 in² and weighs 2.86 lb/ft. Its strong-axis moment of inertia is 13.031 in⁴ gross and 10.490 in⁴ effective at yield, and its effective section modulus is 1.815 in³. With the flange braced, its allowable moment is 33.8 kip·in (ASD), governed by local buckling (§F3).

10″3-1/2″1″ lipt = 0.0451″

Dimensions

Depth10in
Flange width3-1/2in
Lip length1in
Design thickness0.0451in
Minimum thickness0.0428in
Inside bend radius0.0712in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.842in²
Weight2.86lb/ft
Ix13.031in⁴
Sx2.606in³
rx3.935in
Iy1.429in⁴
Sy0.574in³
ry1.303in

Torsion and effective section

J0.571×10⁻³ in⁴
Cw28.978in⁶
xo-2.557in
ro4.871in
β0.724
Ixe at yield10.490in⁴
Sxe1.815in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)56.4433.8050.79§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)59.8935.8653.90§F3.1 · kip·in
Shear, web without holes2.221.111.77§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)9.545.308.11§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)9.535.308.10§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)9.535.298.10§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)9.515.288.08§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)9.445.248.02§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)9.305.177.91§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.09 at 7.6 inDistortional0.36 at 47.2 in
Signature curve of the 1000S350-43 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (M/My)Local0.48 at 5.5 inDistortional0.82 at 46.2 in
Signature curve of the 1000S350-43 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py27.77kip
Pcrℓ at 7.62.61kip
Pcrd at 47.29.97kip
My86.00kip·in
Mcrℓ at 5.541.63kip·in
Mcrd at 46.270.47kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
2.61 kip at 7.6 in
Distortional
9.97 kip at 47.2 in
Buckled shapes of the 1000S350-43 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1000S350-43 mean?

1000S350-43 is an SSMA designation: 10 in stud or joist, 3-1/2 in flange, 43 mil (0.0451 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0451 in.

What are the section properties of a 1000S350-43 stud?

Area 0.842 in², weight 2.86 lb/ft, Ix 13.031 in⁴, Sx 2.606 in³, rx 3.935 in, Iy 1.429 in⁴, ry 1.303 in, J 0.571 ×10⁻³ in⁴, Cw 28.978 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1000S350-43?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 56.4 kip·in by the Direct Strength Method (governed by §F3.2): 33.8 kip·in allowable (ASD) or 50.8 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1000S350-43?

By finite strip analysis, local buckling in compression occurs at 2.61 kip (half-wavelength 7.6 in) and distortional buckling at 9.97 kip (47.2 in), against a squash load Py of 27.77 kip.

Other 10 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation