1000S250-97 stud properties and strength

SSMA 10 in stud or joist, 2-1/2 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1000S250-97 has an area of 1.576 in² and weighs 5.36 lb/ft. Its strong-axis moment of inertia is 21.827 in⁴ gross and 21.349 in⁴ effective at yield, and its effective section modulus is 4.213 in³. With the flange braced, its allowable moment is 116.4 kip·in (ASD), governed by distortional buckling (§F4).

10″2-1/2″0.625″ lipt = 0.1017″

Dimensions

Depth10in
Flange width2-1/2in
Lip length0.625in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.576in²
Weight5.36lb/ft
Ix21.827in⁴
Sx4.365in³
rx3.722in
Iy1.073in⁴
Sy0.557in³
ry0.825in

Torsion and effective section

J5.433×10⁻³ in⁴
Cw20.183in⁶
xo-1.441in
ro4.075in
β0.875
Ixe at yield21.349in⁴
Sxe4.213in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)194.39116.40174.95§F4 · kip·in
Strong-axis moment, flange braced (EWM)194.34116.37174.91§F4 · kip·in
Shear, web without holes16.9810.1715.29§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)39.4221.9033.50§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)39.4221.9033.50§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)39.4221.9033.50§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)39.4221.9033.50§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)39.4221.9033.50§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)39.4221.9033.50§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.32 at 7.9 inDistortional (by cFSM)0.41 at 21.3 in
Signature curve of the 1000S250-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.01101001000half-wavelength, in (log scale)load factor (M/My)Local1.77 at 5.8 inDistortional1.42 at 16.4 in
Signature curve of the 1000S250-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py78.79kip
Pcrℓ at 7.925.39kip
Pcrd at 21.332.12kip
My218.27kip·in
Mcrℓ at 5.8386.38kip·in
Mcrd at 16.4309.44kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
25.39 kip at 7.9 in
Distortional
32.12 kip at 21.3 in
Buckled shapes of the 1000S250-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1000S250-97 mean?

1000S250-97 is an SSMA designation: 10 in stud or joist, 2-1/2 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 1000S250-97 stud?

Area 1.576 in², weight 5.36 lb/ft, Ix 21.827 in⁴, Sx 4.365 in³, rx 3.722 in, Iy 1.073 in⁴, ry 0.825 in, J 5.433 ×10⁻³ in⁴, Cw 20.183 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1000S250-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 194.4 kip·in by the Direct Strength Method (governed by §F4): 116.4 kip·in allowable (ASD) or 174.9 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1000S250-97?

By finite strip analysis, local buckling in compression occurs at 25.39 kip (half-wavelength 7.9 in) and distortional buckling at 32.12 kip (21.3 in), against a squash load Py of 78.79 kip.

Other 10 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation