800S300-68 stud properties and strength

SSMA 8 in stud or joist, 3 in flange, 68 mil (0.0713 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800S300-68 has an area of 1.050 in² and weighs 3.57 lb/ft. Its strong-axis moment of inertia is 10.382 in⁴ gross and 9.216 in⁴ effective at yield, and its effective section modulus is 2.148 in³. With the flange braced, its allowable moment is 57.6 kip·in (ASD), governed by distortional buckling (§F4).

8″3″0.625″ lipt = 0.0713″

Dimensions

Depth8in
Flange width3in
Lip length0.625in
Design thickness0.0713in
Minimum thickness0.0677in
Inside bend radius0.1070in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.050in²
Weight3.57lb/ft
Ix10.382in⁴
Sx2.595in³
rx3.145in
Iy1.179in⁴
Sy0.543in³
ry1.060in

Torsion and effective section

J1.779×10⁻³ in⁴
Cw14.250in⁶
xo-2.048in
ro3.900in
β0.724
Ixe at yield9.216in⁴
Sxe2.148in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)96.1357.5686.52§F4 · kip·in
Strong-axis moment, flange braced (EWM)96.1157.5586.50§F4 · kip·in
Shear, web without holes8.244.947.42§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)24.3013.5020.65§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)24.2813.4920.64§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)24.2613.4820.62§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)24.1513.4220.53§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)23.7913.2220.22§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)23.0612.8119.60§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.24 at 6.1 inDistortional0.41 at 22.2 in
Signature curve of the 800S300-68 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.01101001000half-wavelength, in (log scale)load factor (M/My)Local1.21 at 4.4 inDistortional0.86 at 22.3 in
Signature curve of the 800S300-68 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py52.48kip
Pcrℓ at 6.112.75kip
Pcrd at 22.221.70kip
My129.77kip·in
Mcrℓ at 4.4157.66kip·in
Mcrd at 22.3111.97kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
12.75 kip at 6.1 in
Distortional
21.70 kip at 22.2 in
Buckled shapes of the 800S300-68 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800S300-68 mean?

800S300-68 is an SSMA designation: 8 in stud or joist, 3 in flange, 68 mil (0.0713 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0713 in.

What are the section properties of a 800S300-68 stud?

Area 1.050 in², weight 3.57 lb/ft, Ix 10.382 in⁴, Sx 2.595 in³, rx 3.145 in, Iy 1.179 in⁴, ry 1.060 in, J 1.779 ×10⁻³ in⁴, Cw 14.250 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800S300-68?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 96.1 kip·in by the Direct Strength Method (governed by §F4): 57.6 kip·in allowable (ASD) or 86.5 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800S300-68?

By finite strip analysis, local buckling in compression occurs at 12.75 kip (half-wavelength 6.1 in) and distortional buckling at 21.70 kip (22.2 in), against a squash load Py of 52.48 kip.

Other 8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation