800S162-97 stud properties and strength

SSMA 8 in stud or joist, 1-5/8 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800S162-97 has an area of 1.169 in² and weighs 3.98 lb/ft. Its strong-axis moment of inertia is 9.714 in⁴ gross and 9.714 in⁴ effective at yield, and its effective section modulus is 2.428 in³. With the flange braced, its allowable moment is 73.0 kip·in (ASD), governed by distortional buckling (§F4).

8″1-5/8″0.5″ lipt = 0.1017″

Dimensions

Depth8in
Flange width1-5/8in
Lip length0.5in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.169in²
Weight3.98lb/ft
Ix9.714in⁴
Sx2.428in³
rx2.883in
Iy0.305in⁴
Sy0.239in³
ry0.511in

Torsion and effective section

J4.030×10⁻³ in⁴
Cw3.716in⁶
xo-0.852in
ro3.049in
β0.922
Ixe at yield9.714in⁴
Sxe2.428in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)121.9673.03109.77§F4 · kip·in
Strong-axis moment, flange braced (EWM)121.4272.71109.28§F2.1 · kip·in
Shear, web without holes16.619.9414.95§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)25.5614.2021.72§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)25.5614.2021.72§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)25.5614.2021.72§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)25.5614.2021.72§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)25.5614.2021.72§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)25.5614.2021.72§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.47 at 8.8 inDistortional (by cFSM)0.52 at 14.1 in
Signature curve of the 800S162-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.51101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)2.80 at 4.1 inDistortional2.20 at 9.8 in
Signature curve of the 800S162-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py58.45kip
Pcrℓ at 8.827.56kip
Pcrd at 14.130.24kip
My121.42kip·in
Mcrℓ at 4.1339.85kip·in
Mcrd at 9.8267.24kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
27.56 kip at 8.8 in
Distortional
30.24 kip at 14.1 in
Buckled shapes of the 800S162-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800S162-97 mean?

800S162-97 is an SSMA designation: 8 in stud or joist, 1-5/8 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 800S162-97 stud?

Area 1.169 in², weight 3.98 lb/ft, Ix 9.714 in⁴, Sx 2.428 in³, rx 2.883 in, Iy 0.305 in⁴, ry 0.511 in, J 4.030 ×10⁻³ in⁴, Cw 3.716 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800S162-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 122.0 kip·in by the Direct Strength Method (governed by §F4): 73.0 kip·in allowable (ASD) or 109.8 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800S162-97?

By finite strip analysis, local buckling in compression occurs at 27.56 kip (half-wavelength 8.8 in) and distortional buckling at 30.24 kip (14.1 in), against a squash load Py of 58.45 kip.

Other 8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation