800S200-118 stud properties and strength

SSMA 8 in stud or joist, 2 in flange, 118 mil (0.1242 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800S200-118 has an area of 1.531 in² and weighs 5.21 lb/ft. Its strong-axis moment of inertia is 13.317 in⁴ gross and 13.317 in⁴ effective at yield, and its effective section modulus is 3.329 in³. With the flange braced, its allowable moment is 102.9 kip·in (ASD), governed by distortional buckling (§F4).

8″2″0.625″ lipt = 0.1242″

Dimensions

Depth8in
Flange width2in
Lip length0.625in
Design thickness0.1242in
Minimum thickness0.1180in
Inside bend radius0.1863in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.531in²
Weight5.21lb/ft
Ix13.317in⁴
Sx3.329in³
rx2.949in
Iy0.666in⁴
Sy0.440in³
ry0.659in

Torsion and effective section

J7.872×10⁻³ in⁴
Cw8.102in⁶
xo-1.173in
ro3.242in
β0.869
Ixe at yield13.317in⁴
Sxe3.329in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)171.79102.87154.61§F4 · kip·in
Strong-axis moment, flange braced (EWM)166.4699.67149.81§F3.1 · kip·in
Shear, web without holes23.1713.8720.85§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)45.5325.3038.70§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)45.5325.3038.70§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)45.5325.3038.70§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)45.5325.3038.70§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)45.5325.3038.70§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)45.5325.3038.70§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.74 at 7.0 inDistortional (by cFSM)0.82 at 15.6 in
Signature curve of the 800S200-118 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.08.59.09.51101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)4.18 at 4.2 inDistortional2.84 at 11.8 in
Signature curve of the 800S200-118 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py76.55kip
Pcrℓ at 7.056.95kip
Pcrd at 15.662.79kip
My166.46kip·in
Mcrℓ at 4.2695.01kip·in
Mcrd at 11.8472.84kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
56.95 kip at 7.0 in
Distortional
62.79 kip at 15.6 in
Buckled shapes of the 800S200-118 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800S200-118 mean?

800S200-118 is an SSMA designation: 8 in stud or joist, 2 in flange, 118 mil (0.1242 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1242 in.

What are the section properties of a 800S200-118 stud?

Area 1.531 in², weight 5.21 lb/ft, Ix 13.317 in⁴, Sx 3.329 in³, rx 2.949 in, Iy 0.666 in⁴, ry 0.659 in, J 7.872 ×10⁻³ in⁴, Cw 8.102 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800S200-118?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 171.8 kip·in by the Direct Strength Method (governed by §F4): 102.9 kip·in allowable (ASD) or 154.6 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800S200-118?

By finite strip analysis, local buckling in compression occurs at 56.95 kip (half-wavelength 7.0 in) and distortional buckling at 62.79 kip (15.6 in), against a squash load Py of 76.55 kip.

Other 8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation