800S250-97 stud properties and strength

SSMA 8 in stud or joist, 2-1/2 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800S250-97 has an area of 1.372 in² and weighs 4.67 lb/ft. Its strong-axis moment of inertia is 12.790 in⁴ gross and 12.501 in⁴ effective at yield, and its effective section modulus is 3.079 in³. With the flange braced, its allowable moment is 87.8 kip·in (ASD), governed by distortional buckling (§F4).

8″2-1/2″0.625″ lipt = 0.1017″

Dimensions

Depth8in
Flange width2-1/2in
Lip length0.625in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.372in²
Weight4.67lb/ft
Ix12.790in⁴
Sx3.197in³
rx3.053in
Iy1.009in⁴
Sy0.546in³
ry0.858in

Torsion and effective section

J4.731×10⁻³ in⁴
Cw12.182in⁶
xo-1.596in
ro3.550in
β0.798
Ixe at yield12.501in⁴
Sxe3.079in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)146.5687.76131.90§F4 · kip·in
Strong-axis moment, flange braced (EWM)146.5387.74131.88§F4 · kip·in
Shear, web without holes16.619.9414.95§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)40.5122.5034.43§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)40.4922.4934.42§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)40.4622.4834.39§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)40.3622.4234.31§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)39.9922.2233.99§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)38.7921.5532.98§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.50 at 6.2 inDistortional (by cFSM)0.66 at 19.3 in
Signature curve of the 800S250-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.01101001000half-wavelength, in (log scale)load factor (M/My)Local2.68 at 4.6 inDistortional1.72 at 15.8 in
Signature curve of the 800S250-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py68.62kip
Pcrℓ at 6.234.60kip
Pcrd at 19.345.46kip
My159.87kip·in
Mcrℓ at 4.6428.30kip·in
Mcrd at 15.8275.08kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
34.60 kip at 6.2 in
Distortional
45.46 kip at 19.3 in
Buckled shapes of the 800S250-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800S250-97 mean?

800S250-97 is an SSMA designation: 8 in stud or joist, 2-1/2 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 800S250-97 stud?

Area 1.372 in², weight 4.67 lb/ft, Ix 12.790 in⁴, Sx 3.197 in³, rx 3.053 in, Iy 1.009 in⁴, ry 0.858 in, J 4.731 ×10⁻³ in⁴, Cw 12.182 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800S250-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 146.6 kip·in by the Direct Strength Method (governed by §F4): 87.8 kip·in allowable (ASD) or 131.9 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800S250-97?

By finite strip analysis, local buckling in compression occurs at 34.60 kip (half-wavelength 6.2 in) and distortional buckling at 45.46 kip (19.3 in), against a squash load Py of 68.62 kip.

Other 8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation