600S162-97 stud properties and strength

SSMA 6 in stud or joist, 1-5/8 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 600S162-97 has an area of 0.966 in² and weighs 3.29 lb/ft. Its strong-axis moment of inertia is 4.798 in⁴ gross and 4.798 in⁴ effective at yield, and its effective section modulus is 1.599 in³. With the flange braced, its allowable moment is 49.8 kip·in (ASD), governed by distortional buckling (§F4).

6″1-5/8″0.5″ lipt = 0.1017″

Dimensions

Depth6in
Flange width1-5/8in
Lip length0.5in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.966in²
Weight3.29lb/ft
Ix4.798in⁴
Sx1.599in³
rx2.229in
Iy0.283in⁴
Sy0.233in³
ry0.542in

Torsion and effective section

J3.329×10⁻³ in⁴
Cw1.936in⁶
xo-0.985in
ro2.496in
β0.844
Ixe at yield4.798in⁴
Sxe1.599in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)83.1049.7674.79§F4 · kip·in
Strong-axis moment, flange braced (EWM)79.9647.8871.97§F2.1 · kip·in
Shear, web without holes14.898.9213.40§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)25.9514.4122.05§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)25.9514.4122.05§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)25.9514.4122.05§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)25.9514.4122.05§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)25.9514.4122.05§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)25.9514.4122.05§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.02.51101001000half-wavelength, in (log scale)load factor (P/Py)Local0.89 at 5.1 inDistortional (by cFSM)0.98 at 12.0 in
Signature curve of the 600S162-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.08.59.09.510.010.511.01101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)4.94 at 3.2 inDistortional3.09 at 9.3 in
Signature curve of the 600S162-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py48.28kip
Pcrℓ at 5.143.09kip
Pcrd at 12.047.26kip
My79.96kip·in
Mcrℓ at 3.2394.77kip·in
Mcrd at 9.3246.71kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
43.09 kip at 5.1 in
Distortional
47.26 kip at 12.0 in
Buckled shapes of the 600S162-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 600S162-97 mean?

600S162-97 is an SSMA designation: 6 in stud or joist, 1-5/8 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 600S162-97 stud?

Area 0.966 in², weight 3.29 lb/ft, Ix 4.798 in⁴, Sx 1.599 in³, rx 2.229 in, Iy 0.283 in⁴, ry 0.542 in, J 3.329 ×10⁻³ in⁴, Cw 1.936 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 600S162-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 83.1 kip·in by the Direct Strength Method (governed by §F4): 49.8 kip·in allowable (ASD) or 74.8 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 600S162-97?

By finite strip analysis, local buckling in compression occurs at 43.09 kip (half-wavelength 5.1 in) and distortional buckling at 47.26 kip (12.0 in), against a squash load Py of 48.28 kip.

Other 6 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation