550S137-68 stud properties and strength

SSMA 5-1/2 in stud or joist, 1-3/8 in flange, 68 mil (0.0713 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 550S137-68 has an area of 0.604 in² and weighs 2.05 lb/ft. Its strong-axis moment of inertia is 2.503 in⁴ gross and 2.503 in⁴ effective at yield, and its effective section modulus is 0.910 in³. With the flange braced, its allowable moment is 26.5 kip·in (ASD), governed by distortional buckling (§F4).

5-1/2″1-3/8″0.375″ lipt = 0.0713″

Dimensions

Depth5-1/2in
Flange width1-3/8in
Lip length0.375in
Design thickness0.0713in
Minimum thickness0.0677in
Inside bend radius0.1070in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.604in²
Weight2.05lb/ft
Ix2.503in⁴
Sx0.910in³
rx2.036in
Iy0.123in⁴
Sy0.117in³
ry0.451in

Torsion and effective section

J1.023×10⁻³ in⁴
Cw0.699in⁶
xo-0.792in
ro2.231in
β0.874
Ixe at yield2.503in⁴
Sxe0.910in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)44.2926.5239.86§F4 · kip·in
Strong-axis moment, flange braced (EWM)44.2826.5239.85§F4 · kip·in
Shear, web without holes8.124.867.31§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)11.856.5810.07§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)11.856.5810.07§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)11.856.5810.07§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)11.856.5810.07§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)11.856.5810.07§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)11.856.5810.07§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.52 at 4.6 inDistortional (by cFSM)0.60 at 10.9 in
Signature curve of the 550S137-68 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.51101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)2.89 at 2.9 inDistortional2.07 at 8.3 in
Signature curve of the 550S137-68 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py30.20kip
Pcrℓ at 4.615.67kip
Pcrd at 10.918.06kip
My45.51kip·in
Mcrℓ at 2.9131.61kip·in
Mcrd at 8.394.16kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
15.67 kip at 4.6 in
Distortional
18.06 kip at 10.9 in
Buckled shapes of the 550S137-68 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 550S137-68 mean?

550S137-68 is an SSMA designation: 5-1/2 in stud or joist, 1-3/8 in flange, 68 mil (0.0713 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0713 in.

What are the section properties of a 550S137-68 stud?

Area 0.604 in², weight 2.05 lb/ft, Ix 2.503 in⁴, Sx 0.910 in³, rx 2.036 in, Iy 0.123 in⁴, ry 0.451 in, J 1.023 ×10⁻³ in⁴, Cw 0.699 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 550S137-68?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 44.3 kip·in by the Direct Strength Method (governed by §F4): 26.5 kip·in allowable (ASD) or 39.9 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 550S137-68?

By finite strip analysis, local buckling in compression occurs at 15.67 kip (half-wavelength 4.6 in) and distortional buckling at 18.06 kip (10.9 in), against a squash load Py of 30.20 kip.

Other 5-1/2 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation