550S125-68 stud properties and strength

SSMA 5-1/2 in stud or joist, 1-1/4 in flange, 68 mil (0.0713 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 550S125-68 has an area of 0.559 in² and weighs 1.90 lb/ft. Its strong-axis moment of inertia is 2.209 in⁴ gross and 2.193 in⁴ effective at yield, and its effective section modulus is 0.794 in³. With the flange braced, its allowable moment is 22.8 kip·in (ASD), governed by distortional buckling (§F4).

5-1/2″1-1/4″0.188″ lipt = 0.0713″

Dimensions

Depth5-1/2in
Flange width1-1/4in
Lip length0.188in
Design thickness0.0713in
Minimum thickness0.0677in
Inside bend radius0.1070in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.559in²
Weight1.90lb/ft
Ix2.209in⁴
Sx0.803in³
rx1.987in
Iy0.072in⁴
Sy0.071in³
ry0.359in

Torsion and effective section

J0.948×10⁻³ in⁴
Cw0.393in⁶
xo-0.584in
ro2.102in
β0.923
Ixe at yield2.193in⁴
Sxe0.794in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)38.1322.8334.32§F4 · kip·in
Strong-axis moment, flange braced (EWM)38.1222.8234.30§F4 · kip·in
Shear, web without holes8.124.867.31§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)7.504.166.37§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)7.504.166.37§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)7.504.166.37§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)7.504.166.37§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)7.504.166.37§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)7.504.166.37§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.43 at 5.8 inDistortional (by cFSM)0.47 at 8.2 in
Signature curve of the 550S125-68 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.01101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)2.17 at 2.9 inDistortional1.70 at 5.0 in
Signature curve of the 550S125-68 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py27.97kip
Pcrℓ at 5.812.12kip
Pcrd at 8.213.21kip
My40.17kip·in
Mcrℓ at 2.987.30kip·in
Mcrd at 5.068.25kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
12.12 kip at 5.8 in
Distortional
13.21 kip at 8.2 in
Buckled shapes of the 550S125-68 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 550S125-68 mean?

550S125-68 is an SSMA designation: 5-1/2 in stud or joist, 1-1/4 in flange, 68 mil (0.0713 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0713 in.

What are the section properties of a 550S125-68 stud?

Area 0.559 in², weight 1.90 lb/ft, Ix 2.209 in⁴, Sx 0.803 in³, rx 1.987 in, Iy 0.072 in⁴, ry 0.359 in, J 0.948 ×10⁻³ in⁴, Cw 0.393 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 550S125-68?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 38.1 kip·in by the Direct Strength Method (governed by §F4): 22.8 kip·in allowable (ASD) or 34.3 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 550S125-68?

By finite strip analysis, local buckling in compression occurs at 12.12 kip (half-wavelength 5.8 in) and distortional buckling at 13.21 kip (8.2 in), against a squash load Py of 27.97 kip.

Other 5-1/2 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation