1400T200-54 track properties and strength

SSMA 14 in track, 2 in flange, 54 mil (0.0566 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1400T200-54 has an area of 1.013 in² and weighs 3.45 lb/ft. Its strong-axis moment of inertia is 23.852 in⁴ gross and 14.583 in⁴ effective at yield, and its effective section modulus is 1.579 in³. With the flange braced, its allowable moment is 52.5 kip·in (ASD), governed by local buckling (§F3).

14-1/8″2″t = 0.0566″

Dimensions

Depth (inside)14in
Flange width2in
Design thickness0.0566in
Minimum thickness0.0538in
Inside bend radius0.0849in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.013in²
Weight3.45lb/ft
Ix23.852in⁴
Sx3.380in³
rx4.852in
Iy0.241in⁴
Sy0.138in³
ry0.488in

Torsion and effective section

J1.082×10⁻³ in⁴
Cw9.321in⁶
xo-0.673in
ro4.922in
β0.981
Ixe at yield14.583in⁴
Sxe1.579in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)87.6052.4678.84§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)78.9747.2971.07§F3.1 · kip·in
Shear, web without holes3.451.722.76§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)8.624.797.32§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)8.624.797.32§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)8.624.797.32§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)8.624.797.32§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)8.624.797.32§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)8.624.797.32§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.04 at 13.9 in
Signature curve of the 1400T200-54 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (M/My)Local0.21 at 9.7 in
Signature curve of the 1400T200-54 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py50.67kip
Pcrℓ at 13.91.98kip
My169.01kip·in
Mcrℓ at 9.734.87kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
1.98 kip at 13.9 in
Buckled shapes of the 1400T200-54 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1400T200-54 mean?

1400T200-54 is an SSMA designation: 14 in track, 2 in flange, 54 mil (0.0566 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0566 in.

What are the section properties of a 1400T200-54 track?

Area 1.013 in², weight 3.45 lb/ft, Ix 23.852 in⁴, Sx 3.380 in³, rx 4.852 in, Iy 0.241 in⁴, ry 0.488 in, J 1.082 ×10⁻³ in⁴, Cw 9.321 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1400T200-54?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 87.6 kip·in by the Direct Strength Method (governed by §F3.2): 52.5 kip·in allowable (ASD) or 78.8 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1400T200-54?

By finite strip analysis, local buckling in compression occurs at 1.98 kip (half-wavelength 13.9 in), against a squash load Py of 50.67 kip.

Other 14 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation