1400T125-97 track properties and strength

SSMA 14 in track, 1-1/4 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1400T125-97 has an area of 1.660 in² and weighs 5.65 lb/ft. Its strong-axis moment of inertia is 35.000 in⁴ gross and 31.521 in⁴ effective at yield, and its effective section modulus is 4.081 in³. With the flange braced, its allowable moment is 127.3 kip·in (ASD), governed by local buckling (§F3).

14-1/4″1-1/4″t = 0.1017″

Dimensions

Depth (inside)14in
Flange width1-1/4in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.660in²
Weight5.65lb/ft
Ix35.000in⁴
Sx4.928in³
rx4.591in
Iy0.104in⁴
Sy0.094in³
ry0.250in

Torsion and effective section

J5.724×10⁻³ in⁴
Cw4.267in⁶
xo-0.296in
ro4.608in
β0.996
Ixe at yield31.521in⁴
Sxe4.081in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)212.67127.35191.40§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)204.06122.19183.65§F3.1 · kip·in
Shear, web without holes15.789.4514.20§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)9.405.227.99§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)9.405.227.99§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)9.405.227.99§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)9.405.227.99§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)9.405.227.99§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)9.405.227.99§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.12 at 14.7 in
Signature curve of the 1400T125-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (M/My)Local0.70 at 10.0 in
Signature curve of the 1400T125-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py83.01kip
Pcrℓ at 14.79.86kip
My246.42kip·in
Mcrℓ at 10.0172.17kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
9.86 kip at 14.7 in
Buckled shapes of the 1400T125-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1400T125-97 mean?

1400T125-97 is an SSMA designation: 14 in track, 1-1/4 in flange, 97 mil (0.1017 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 1400T125-97 track?

Area 1.660 in², weight 5.65 lb/ft, Ix 35.000 in⁴, Sx 4.928 in³, rx 4.591 in, Iy 0.104 in⁴, ry 0.250 in, J 5.724 ×10⁻³ in⁴, Cw 4.267 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1400T125-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 212.7 kip·in by the Direct Strength Method (governed by §F3.2): 127.3 kip·in allowable (ASD) or 191.4 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1400T125-97?

By finite strip analysis, local buckling in compression occurs at 9.86 kip (half-wavelength 14.7 in), against a squash load Py of 83.01 kip.

Other 14 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation