1400S350-33 stud properties and strength

SSMA 14 in stud or joist, 3-1/2 in flange, 33 mil (0.0346 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1400S350-33 has an area of 0.785 in² and weighs 2.67 lb/ft. Its strong-axis moment of inertia is 22.144 in⁴ gross and 14.379 in⁴ effective at yield, and its effective section modulus is 1.578 in³. With the flange braced, its allowable moment is 22.6 kip·in (ASD), governed by local buckling (§F3).

14″3-1/2″1″ lipt = 0.0346″

Dimensions

Depth14in
Flange width3-1/2in
Lip length1in
Design thickness0.0346in
Minimum thickness0.0329in
Inside bend radius0.0765in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.785in²
Weight2.67lb/ft
Ix22.144in⁴
Sx3.163in³
rx5.310in
Iy1.219in⁴
Sy0.457in³
ry1.246in

Torsion and effective section

J0.313×10⁻³ in⁴
Cw46.862in⁶
xo-2.225in
ro5.890in
β0.857
Ixe at yield14.379in⁴
Sxe1.578in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)45.1522.5736.12§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)52.0731.1846.87§F3.1 · kip·in
Shear, web without holes0.830.420.67§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)6.543.275.23§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)6.543.275.23§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)6.543.275.23§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)6.543.275.23§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)6.543.275.23§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)6.543.275.23§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.03 at 10.4 inDistortional (by cFSM)0.13 at 65.7 in
Signature curve of the 1400S350-33 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (M/My)Local0.16 at 7.5 inDistortional0.46 at 55.4 in
Signature curve of the 1400S350-33 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py25.92kip
Pcrℓ at 10.40.75kip
Pcrd at 65.73.32kip
My104.39kip·in
Mcrℓ at 7.516.38kip·in
Mcrd at 55.447.74kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
0.75 kip at 10.4 in
Distortional
3.32 kip at 65.7 in
Buckled shapes of the 1400S350-33 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1400S350-33 mean?

1400S350-33 is an SSMA designation: 14 in stud or joist, 3-1/2 in flange, 33 mil (0.0346 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0346 in.

What are the section properties of a 1400S350-33 stud?

Area 0.785 in², weight 2.67 lb/ft, Ix 22.144 in⁴, Sx 3.163 in³, rx 5.310 in, Iy 1.219 in⁴, ry 1.246 in, J 0.313 ×10⁻³ in⁴, Cw 46.862 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1400S350-33?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 45.1 kip·in by the Direct Strength Method (governed by §F3.2): 22.6 kip·in allowable (ASD) or 36.1 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1400S350-33?

By finite strip analysis, local buckling in compression occurs at 0.75 kip (half-wavelength 10.4 in) and distortional buckling at 3.32 kip (65.7 in), against a squash load Py of 25.92 kip.

Other 14 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation