1400S300-97 stud properties and strength

SSMA 14 in stud or joist, 3 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1400S300-97 has an area of 2.084 in² and weighs 7.09 lb/ft. Its strong-axis moment of inertia is 54.675 in⁴ gross and 48.887 in⁴ effective at yield, and its effective section modulus is 6.383 in³. With the flange braced, its allowable moment is 178.9 kip·in (ASD), governed by distortional buckling (§F4).

14″3″0.625″ lipt = 0.1017″

Dimensions

Depth14in
Flange width3in
Lip length0.625in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A2.084in²
Weight7.09lb/ft
Ix54.675in⁴
Sx7.811in³
rx5.122in
Iy1.854in⁴
Sy0.772in³
ry0.943in

Torsion and effective section

J7.186×10⁻³ in⁴
Cw68.150in⁶
xo-1.553in
ro5.435in
β0.918
Ixe at yield48.887in⁴
Sxe6.383in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)298.72178.87268.84§F4 · kip·in
Strong-axis moment, flange braced (EWM)298.61178.81268.74§F4 · kip·in
Shear, web without holes15.869.5014.28§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)35.6719.8130.32§E4 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)35.6719.8130.32§E4 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)35.6719.8130.32§E4 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)35.6719.8130.32§E4 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)35.6719.8130.32§E4 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)35.6719.8130.32§E4 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.16 at 11.7 inDistortional (by cFSM)0.20 at 27.2 in
Signature curve of the 1400S300-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (M/My)Local0.90 at 8.3 inDistortional0.82 at 19.3 in
Signature curve of the 1400S300-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py104.21kip
Pcrℓ at 11.716.85kip
Pcrd at 27.220.57kip
My390.54kip·in
Mcrℓ at 8.3352.23kip·in
Mcrd at 19.3319.68kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
16.85 kip at 11.7 in
Distortional
20.57 kip at 27.2 in
Buckled shapes of the 1400S300-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1400S300-97 mean?

1400S300-97 is an SSMA designation: 14 in stud or joist, 3 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 1400S300-97 stud?

Area 2.084 in², weight 7.09 lb/ft, Ix 54.675 in⁴, Sx 7.811 in³, rx 5.122 in, Iy 1.854 in⁴, ry 0.943 in, J 7.186 ×10⁻³ in⁴, Cw 68.150 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1400S300-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 298.7 kip·in by the Direct Strength Method (governed by §F4): 178.9 kip·in allowable (ASD) or 268.8 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1400S300-97?

By finite strip analysis, local buckling in compression occurs at 16.85 kip (half-wavelength 11.7 in) and distortional buckling at 20.57 kip (27.2 in), against a squash load Py of 104.21 kip.

Other 14 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation