1200S350-97 stud properties and strength
SSMA 12 in stud or joist, 3-1/2 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.
The 1200S350-97 has an area of 2.059 in² and weighs 7.01 lb/ft. Its strong-axis moment of inertia is 43.269 in⁴ gross and 40.970 in⁴ effective at yield, and its effective section modulus is 6.605 in³. With the flange braced, its allowable moment is 179.8 kip·in (ASD), governed by distortional buckling (§F4).
Dimensions
| Depth | 12 | in |
| Flange width | 3-1/2 | in |
| Lip length | 1 | in |
| Design thickness | 0.1017 | in |
| Minimum thickness | 0.0966 | in |
| Inside bend radius | 0.1526 | in |
| Yield stress Fy | 50 | ksi |
| Tensile strength Fu | 65 | ksi |
Gross properties
| Area A | 2.059 | in² |
| Weight | 7.01 | lb/ft |
| Ix | 43.269 | in⁴ |
| Sx | 7.211 | in³ |
| rx | 4.584 | in |
| Iy | 3.159 | in⁴ |
| Sy | 1.220 | in³ |
| ry | 1.239 | in |
Torsion and effective section
| J | 7.098 | ×10⁻³ in⁴ |
| Cw | 88.649 | in⁶ |
| xo | -2.301 | in |
| ro | 5.277 | in |
| β | 0.810 | |
| Ixe at yield | 40.970 | in⁴ |
| Sxe | 6.605 | in³ |
Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.
Available strength (AISI S100-24)
| Action | Nominal | ASD, Rn/Ω | LRFD, φRn | Governed by |
|---|---|---|---|---|
| Strong-axis moment, flange braced (DSM) | 300.25 | 179.79 | 270.23 | §F4 · kip·in |
| Strong-axis moment, flange braced (EWM) | 300.20 | 179.76 | 270.18 | §F4 · kip·in |
| Shear, web without holes | 16.61 | 9.94 | 14.95 | §G2.1 · kip |
| Axial, 8 ft tall, braced at 4 ft (DSM) | 48.54 | 26.97 | 41.26 | §E3.2 · kip |
| Axial, 9 ft tall, braced at 4 ft (DSM) | 48.53 | 26.96 | 41.25 | §E3.2 · kip |
| Axial, 10 ft tall, braced at 4 ft (DSM) | 48.52 | 26.96 | 41.24 | §E3.2 · kip |
| Axial, 12 ft tall, braced at 4 ft (DSM) | 48.48 | 26.93 | 41.21 | §E3.2 · kip |
| Axial, 14 ft tall, braced at 4 ft (DSM) | 48.35 | 26.86 | 41.10 | §E3.2 · kip |
| Axial, 16 ft tall, braced at 4 ft (DSM) | 47.85 | 26.58 | 40.67 | §E3.2 · kip |
Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.
Elastic buckling
Finite strip results
| Py | 102.94 | kip |
| Pcrℓ at 9.0 | 23.15 | kip |
| Pcrd at 36.1 | 42.45 | kip |
| My | 360.57 | kip·in |
| Mcrℓ at 6.5 | 435.97 | kip·in |
| Mcrd at 30.2 | 424.62 | kip·in |
Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.
Quick answers
What does 1200S350-97 mean?
1200S350-97 is an SSMA designation: 12 in stud or joist, 3-1/2 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.
What are the section properties of a 1200S350-97 stud?
Area 2.059 in², weight 7.01 lb/ft, Ix 43.269 in⁴, Sx 7.211 in³, rx 4.584 in, Iy 3.159 in⁴, ry 1.239 in, J 7.098 ×10⁻³ in⁴, Cw 88.649 in⁶, computed by ColdCalc with rounded corners.
What is the allowable moment of a 1200S350-97?
With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 300.3 kip·in by the Direct Strength Method (governed by §F4): 179.8 kip·in allowable (ASD) or 270.2 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.
What are the local and distortional buckling loads of a 1200S350-97?
By finite strip analysis, local buckling in compression occurs at 23.15 kip (half-wavelength 9.0 in) and distortional buckling at 42.45 kip (36.1 in), against a squash load Py of 102.94 kip.
Other 12 in studs
Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation