1200S200-97 stud properties and strength

SSMA 12 in stud or joist, 2 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1200S200-97 has an area of 1.677 in² and weighs 5.71 lb/ft. Its strong-axis moment of inertia is 30.417 in⁴ gross and 29.173 in⁴ effective at yield, and its effective section modulus is 4.660 in³. With the flange braced, its allowable moment is 133.2 kip·in (ASD), governed by distortional buckling (§F4).

12″2″0.625″ lipt = 0.1017″

Dimensions

Depth12in
Flange width2in
Lip length0.625in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.677in²
Weight5.71lb/ft
Ix30.417in⁴
Sx5.070in³
rx4.258in
Iy0.635in⁴
Sy0.392in³
ry0.615in

Torsion and effective section

J5.783×10⁻³ in⁴
Cw17.757in⁶
xo-0.973in
ro4.411in
β0.951
Ixe at yield29.173in⁴
Sxe4.660in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)222.40133.17200.16§F4 · kip·in
Strong-axis moment, flange braced (EWM)222.33133.13200.09§F4 · kip·in
Shear, web without holes16.619.9414.95§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)31.7117.6226.96§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)31.7117.6226.96§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)31.7117.6226.96§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)31.7117.6226.96§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)31.7117.6226.96§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)31.7117.6226.96§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.21 at 12.4 inDistortional (by cFSM)0.24 at 21.4 in
Signature curve of the 1200S200-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.0101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)1.27 at 6.1 inDistortional1.17 at 13.5 in
Signature curve of the 1200S200-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py83.87kip
Pcrℓ at 12.417.81kip
Pcrd at 21.420.03kip
My253.48kip·in
Mcrℓ at 6.1320.72kip·in
Mcrd at 13.5297.21kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
17.81 kip at 12.4 in
Distortional
20.03 kip at 21.4 in
Buckled shapes of the 1200S200-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1200S200-97 mean?

1200S200-97 is an SSMA designation: 12 in stud or joist, 2 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 1200S200-97 stud?

Area 1.677 in², weight 5.71 lb/ft, Ix 30.417 in⁴, Sx 5.070 in³, rx 4.258 in, Iy 0.635 in⁴, ry 0.615 in, J 5.783 ×10⁻³ in⁴, Cw 17.757 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1200S200-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 222.4 kip·in by the Direct Strength Method (governed by §F4): 133.2 kip·in allowable (ASD) or 200.2 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1200S200-97?

By finite strip analysis, local buckling in compression occurs at 17.81 kip (half-wavelength 12.4 in) and distortional buckling at 20.03 kip (21.4 in), against a squash load Py of 83.87 kip.

Other 12 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation