1000T300-68 track properties and strength

SSMA 10 in track, 3 in flange, 68 mil (0.0713 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1000T300-68 has an area of 1.132 in² and weighs 3.85 lb/ft. Its strong-axis moment of inertia is 16.565 in⁴ gross and 11.545 in⁴ effective at yield, and its effective section modulus is 1.887 in³. With the flange braced, its allowable moment is 52.3 kip·in (ASD), governed by local buckling (§F3).

10-1/8″3″t = 0.0713″

Dimensions

Depth (inside)10in
Flange width3in
Design thickness0.0713in
Minimum thickness0.0677in
Inside bend radius0.1070in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.132in²
Weight3.85lb/ft
Ix16.565in⁴
Sx3.267in³
rx3.825in
Iy0.891in⁴
Sy0.370in³
ry0.887in

Torsion and effective section

J1.918×10⁻³ in⁴
Cw16.131in⁶
xo-1.512in
ro4.208in
β0.871
Ixe at yield11.545in⁴
Sxe1.887in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)87.3752.3278.64§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)94.3756.5184.93§F3.1 · kip·in
Shear, web without holes7.704.616.93§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)19.3810.7716.47§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)19.3810.7716.47§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)19.3810.7716.47§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)19.3810.7716.47§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)19.3810.7716.47§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)19.3510.7516.44§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.12 at 10.5 in
Signature curve of the 1000T300-68 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (M/My)Local0.27 at 7.5 in
Signature curve of the 1000T300-68 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py56.60kip
Pcrℓ at 10.56.63kip
My163.33kip·in
Mcrℓ at 7.543.54kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
6.63 kip at 10.5 in
Buckled shapes of the 1000T300-68 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1000T300-68 mean?

1000T300-68 is an SSMA designation: 10 in track, 3 in flange, 68 mil (0.0713 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0713 in.

What are the section properties of a 1000T300-68 track?

Area 1.132 in², weight 3.85 lb/ft, Ix 16.565 in⁴, Sx 3.267 in³, rx 3.825 in, Iy 0.891 in⁴, ry 0.887 in, J 1.918 ×10⁻³ in⁴, Cw 16.131 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1000T300-68?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 87.4 kip·in by the Direct Strength Method (governed by §F3.2): 52.3 kip·in allowable (ASD) or 78.6 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1000T300-68?

By finite strip analysis, local buckling in compression occurs at 6.63 kip (half-wavelength 10.5 in), against a squash load Py of 56.60 kip.

Other 10 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation