1000T200-43 track properties and strength

SSMA 10 in track, 2 in flange, 43 mil (0.0451 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1000T200-43 has an area of 0.628 in² and weighs 2.14 lb/ft. Its strong-axis moment of inertia is 8.217 in⁴ gross and 5.445 in⁴ effective at yield, and its effective section modulus is 0.855 in³. With the flange braced, its allowable moment is 18.9 kip·in (ASD), governed by local buckling (§F3).

10-1/8″2″t = 0.0451″

Dimensions

Depth (inside)10in
Flange width2in
Design thickness0.0451in
Minimum thickness0.0428in
Inside bend radius0.0712in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.628in²
Weight2.14lb/ft
Ix8.217in⁴
Sx1.629in³
rx3.618in
Iy0.183in⁴
Sy0.108in³
ry0.540in

Torsion and effective section

J0.426×10⁻³ in⁴
Cw3.452in⁶
xo-0.822in
ro3.749in
β0.952
Ixe at yield5.445in⁴
Sxe0.855in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)31.5318.8828.37§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)28.2116.8925.39§F3.1 · kip·in
Shear, web without holes2.211.101.77§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)5.413.004.60§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)5.413.004.60§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)5.413.004.60§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)5.413.004.60§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)5.413.004.60§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)5.413.004.60§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.07 at 10.0 in
Signature curve of the 1000T200-43 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (M/My)Local0.31 at 6.8 in
Signature curve of the 1000T200-43 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py20.72kip
Pcrℓ at 10.01.54kip
My53.75kip·in
Mcrℓ at 6.816.43kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
1.54 kip at 10.0 in
Buckled shapes of the 1000T200-43 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1000T200-43 mean?

1000T200-43 is an SSMA designation: 10 in track, 2 in flange, 43 mil (0.0451 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0451 in.

What are the section properties of a 1000T200-43 track?

Area 0.628 in², weight 2.14 lb/ft, Ix 8.217 in⁴, Sx 1.629 in³, rx 3.618 in, Iy 0.183 in⁴, ry 0.540 in, J 0.426 ×10⁻³ in⁴, Cw 3.452 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1000T200-43?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 31.5 kip·in by the Direct Strength Method (governed by §F3.2): 18.9 kip·in allowable (ASD) or 28.4 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1000T200-43?

By finite strip analysis, local buckling in compression occurs at 1.54 kip (half-wavelength 10.0 in), against a squash load Py of 20.72 kip.

Other 10 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation