550T125-68 track properties and strength

SSMA 5-1/2 in track, 1-1/4 in flange, 68 mil (0.0713 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 550T125-68 has an area of 0.562 in² and weighs 1.91 lb/ft. Its strong-axis moment of inertia is 2.302 in⁴ gross and 2.173 in⁴ effective at yield, and its effective section modulus is 0.748 in³. With the flange braced, its allowable moment is 23.5 kip·in (ASD), governed by local buckling (§F3).

5-5/8″1-1/4″t = 0.0713″

Dimensions

Depth (inside)5-1/2in
Flange width1-1/4in
Design thickness0.0713in
Minimum thickness0.0677in
Inside bend radius0.1070in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.562in²
Weight1.91lb/ft
Ix2.302in⁴
Sx0.816in³
rx2.025in
Iy0.065in⁴
Sy0.064in³
ry0.341in

Torsion and effective section

J0.952×10⁻³ in⁴
Cw0.368in⁶
xo-0.541in
ro2.123in
β0.935
Ixe at yield2.173in⁴
Sxe0.748in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)39.1823.4635.26§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)37.4122.4033.67§F3.1 · kip·in
Shear, web without holes8.174.897.36§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)6.823.795.80§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)6.823.795.80§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)6.823.795.80§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)6.823.795.80§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)6.823.795.80§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)6.823.795.80§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.40 at 5.6 in
Signature curve of the 550T125-68 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.51101001000half-wavelength, in (log scale)load factor (M/My)Local1.45 at 3.8 in
Signature curve of the 550T125-68 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py28.08kip
Pcrℓ at 5.611.15kip
My40.80kip·in
Mcrℓ at 3.859.15kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
11.15 kip at 5.6 in
Buckled shapes of the 550T125-68 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 550T125-68 mean?

550T125-68 is an SSMA designation: 5-1/2 in track, 1-1/4 in flange, 68 mil (0.0713 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0713 in.

What are the section properties of a 550T125-68 track?

Area 0.562 in², weight 1.91 lb/ft, Ix 2.302 in⁴, Sx 0.816 in³, rx 2.025 in, Iy 0.065 in⁴, ry 0.341 in, J 0.952 ×10⁻³ in⁴, Cw 0.368 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 550T125-68?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 39.2 kip·in by the Direct Strength Method (governed by §F3.2): 23.5 kip·in allowable (ASD) or 35.3 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 550T125-68?

By finite strip analysis, local buckling in compression occurs at 11.15 kip (half-wavelength 5.6 in), against a squash load Py of 28.08 kip.

Other 5-1/2 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation