400S200-97 stud properties and strength

SSMA 4 in stud or joist, 2 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 400S200-97 has an area of 0.864 in² and weighs 2.94 lb/ft. Its strong-axis moment of inertia is 2.155 in⁴ gross and 2.155 in⁴ effective at yield, and its effective section modulus is 1.078 in³. With the flange braced, its allowable moment is 32.9 kip·in (ASD), governed by distortional buckling (§F4).

4″2″0.625″ lipt = 0.1017″

Dimensions

Depth4in
Flange width2in
Lip length0.625in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.864in²
Weight2.94lb/ft
Ix2.155in⁴
Sx1.078in³
rx1.580in
Iy0.463in⁴
Sy0.354in³
ry0.732in

Torsion and effective section

J2.978×10⁻³ in⁴
Cw1.603in⁶
xo-1.599in
ro2.364in
β0.542
Ixe at yield2.155in⁴
Sxe1.078in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)55.0132.9449.51§F4 · kip·in
Strong-axis moment, flange braced (EWM)53.8832.2748.49§F2.1 · kip·in
Shear, web without holes10.656.389.59§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)26.5514.7522.57§E2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)26.0714.4922.16§E2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)25.2914.0521.49§E2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)22.4412.4719.08§E2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)18.5710.3215.78§E2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)14.658.1412.46§E2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.02.53.03.54.04.51101001000half-wavelength, in (log scale)load factor (P/Py)Local2.02 at 3.1 inDistortional2.00 at 13.4 in
Signature curve of the 400S200-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.08.59.09.510.010.511.011.512.012.513.013.514.014.515.015.516.016.51101001000half-wavelength, in (log scale)load factor (M/My)Local7.46 at 2.1 inDistortional3.52 at 12.0 in
Signature curve of the 400S200-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py43.19kip
Pcrℓ at 3.187.46kip
Pcrd at 13.486.28kip
My53.88kip·in
Mcrℓ at 2.1401.76kip·in
Mcrd at 12.0189.55kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
87.46 kip at 3.1 in
Distortional
86.28 kip at 13.4 in
Buckled shapes of the 400S200-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 400S200-97 mean?

400S200-97 is an SSMA designation: 4 in stud or joist, 2 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 400S200-97 stud?

Area 0.864 in², weight 2.94 lb/ft, Ix 2.155 in⁴, Sx 1.078 in³, rx 1.580 in, Iy 0.463 in⁴, ry 0.732 in, J 2.978 ×10⁻³ in⁴, Cw 1.603 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 400S200-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 55.0 kip·in by the Direct Strength Method (governed by §F4): 32.9 kip·in allowable (ASD) or 49.5 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 400S200-97?

By finite strip analysis, local buckling in compression occurs at 87.46 kip (half-wavelength 3.1 in) and distortional buckling at 86.28 kip (13.4 in), against a squash load Py of 43.19 kip.

Other 4 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation