350S162-97 stud properties and strength

SSMA 3-1/2 in stud or joist, 1-5/8 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 350S162-97 has an area of 0.711 in² and weighs 2.42 lb/ft. Its strong-axis moment of inertia is 1.321 in⁴ gross and 1.321 in⁴ effective at yield, and its effective section modulus is 0.755 in³. With the flange braced, its allowable moment is 23.9 kip·in (ASD), governed by distortional buckling (§F4).

3-1/2″1-5/8″0.5″ lipt = 0.1017″

Dimensions

Depth3-1/2in
Flange width1-5/8in
Lip length0.5in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.711in²
Weight2.42lb/ft
Ix1.321in⁴
Sx0.755in³
rx1.363in
Iy0.238in⁴
Sy0.220in³
ry0.579in

Torsion and effective section

J2.452×10⁻³ in⁴
Cw0.599in⁶
xo-1.233in
ro1.927in
β0.590
Ixe at yield1.321in⁴
Sxe0.755in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)39.9423.9235.95§F4 · kip·in
Strong-axis moment, flange braced (EWM)37.7422.6033.96§F2.1 · kip·in
Shear, web without holes9.135.478.21§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)19.3010.7216.40§E2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)18.7710.4315.96§E2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)17.909.9515.22§E2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)15.028.3412.76§E2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)11.606.449.86§E2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)9.015.017.66§E2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.02.53.03.54.04.55.05.56.01101001000half-wavelength, in (log scale)load factor (P/Py)Local2.69 at 2.7 inDistortional2.40 at 9.4 in
Signature curve of the 350S162-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.08.59.09.510.010.511.011.512.012.513.013.514.014.515.015.516.016.517.017.518.018.519.019.520.020.521.021.522.022.523.023.524.024.51101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)11.13 at 1.8 inDistortional4.41 at 8.4 in
Signature curve of the 350S162-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py35.56kip
Pcrℓ at 2.795.57kip
Pcrd at 9.485.26kip
My37.74kip·in
Mcrℓ at 1.8420.02kip·in
Mcrd at 8.4166.46kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
95.57 kip at 2.7 in
Distortional
85.26 kip at 9.4 in
Buckled shapes of the 350S162-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 350S162-97 mean?

350S162-97 is an SSMA designation: 3-1/2 in stud or joist, 1-5/8 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 350S162-97 stud?

Area 0.711 in², weight 2.42 lb/ft, Ix 1.321 in⁴, Sx 0.755 in³, rx 1.363 in, Iy 0.238 in⁴, ry 0.579 in, J 2.452 ×10⁻³ in⁴, Cw 0.599 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 350S162-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 39.9 kip·in by the Direct Strength Method (governed by §F4): 23.9 kip·in allowable (ASD) or 35.9 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 350S162-97?

By finite strip analysis, local buckling in compression occurs at 95.57 kip (half-wavelength 2.7 in) and distortional buckling at 85.26 kip (9.4 in), against a squash load Py of 35.56 kip.

Other 3-1/2 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation