1200T125-97 track properties and strength
SSMA 12 in track, 1-1/4 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.
The 1200T125-97 has an area of 1.457 in² and weighs 4.96 lb/ft. Its strong-axis moment of inertia is 23.293 in⁴ gross and 21.849 in⁴ effective at yield, and its effective section modulus is 3.390 in³. With the flange braced, its allowable moment is 106.6 kip·in (ASD), governed by local buckling (§F3).
Dimensions
| Depth (inside) | 12 | in |
| Flange width | 1-1/4 | in |
| Design thickness | 0.1017 | in |
| Minimum thickness | 0.0966 | in |
| Inside bend radius | 0.1526 | in |
| Yield stress Fy | 50 | ksi |
| Tensile strength Fu | 65 | ksi |
Gross properties
| Area A | 1.457 | in² |
| Weight | 4.96 | lb/ft |
| Ix | 23.293 | in⁴ |
| Sx | 3.817 | in³ |
| rx | 3.999 | in |
| Iy | 0.102 | in⁴ |
| Sy | 0.093 | in³ |
| ry | 0.265 | in |
Torsion and effective section
| J | 5.023 | ×10⁻³ in⁴ |
| Cw | 3.021 | in⁶ |
| xo | -0.330 | in |
| ro | 4.021 | in |
| β | 0.993 | |
| Ixe at yield | 21.849 | in⁴ |
| Sxe | 3.390 | in³ |
Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.
Available strength (AISI S100-24)
| Action | Nominal | ASD, Rn/Ω | LRFD, φRn | Governed by |
|---|---|---|---|---|
| Strong-axis moment, flange braced (DSM) | 178.04 | 106.61 | 160.23 | §F3.2 · kip·in |
| Strong-axis moment, flange braced (EWM) | 169.49 | 101.49 | 152.54 | §F3.1 · kip·in |
| Shear, web without holes | 16.54 | 9.91 | 14.89 | §G2.1 · kip |
| Axial, 8 ft tall, braced at 4 ft (DSM) | 9.77 | 5.43 | 8.30 | §E3.2 · kip |
| Axial, 9 ft tall, braced at 4 ft (DSM) | 9.77 | 5.43 | 8.30 | §E3.2 · kip |
| Axial, 10 ft tall, braced at 4 ft (DSM) | 9.77 | 5.43 | 8.30 | §E3.2 · kip |
| Axial, 12 ft tall, braced at 4 ft (DSM) | 9.77 | 5.43 | 8.30 | §E3.2 · kip |
| Axial, 14 ft tall, braced at 4 ft (DSM) | 9.77 | 5.43 | 8.30 | §E3.2 · kip |
| Axial, 16 ft tall, braced at 4 ft (DSM) | 9.77 | 5.43 | 8.30 | §E3.2 · kip |
Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.
Elastic buckling
Finite strip results
| Py | 72.84 | kip |
| Pcrℓ at 12.5 | 11.91 | kip |
| My | 190.87 | kip·in |
| Mcrℓ at 8.6 | 180.74 | kip·in |
Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.
Quick answers
What does 1200T125-97 mean?
1200T125-97 is an SSMA designation: 12 in track, 1-1/4 in flange, 97 mil (0.1017 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.
What are the section properties of a 1200T125-97 track?
Area 1.457 in², weight 4.96 lb/ft, Ix 23.293 in⁴, Sx 3.817 in³, rx 3.999 in, Iy 0.102 in⁴, ry 0.265 in, J 5.023 ×10⁻³ in⁴, Cw 3.021 in⁶, computed by ColdCalc with rounded corners.
What is the allowable moment of a 1200T125-97?
With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 178.0 kip·in by the Direct Strength Method (governed by §F3.2): 106.6 kip·in allowable (ASD) or 160.2 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.
What are the local and distortional buckling loads of a 1200T125-97?
By finite strip analysis, local buckling in compression occurs at 11.91 kip (half-wavelength 12.5 in), against a squash load Py of 72.84 kip.
Other 12 in tracks
Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation