Inputs

Eccentricity

Where the axial load acts on the section, measured from the centroid: click the section in the popover or type eₓ and eᵧ. It adds a moment P·e at the top, falling to zero at a pinned bottom.

e_y is along the web, toward the top flange (the one sheathing braces on a stud); e_x is across the web, toward the flange tips. A joist or truss bearing on one flange, or a brick ledge, loads a stud eccentrically. A load off the shear center also twists the member.

Typical values
0 for concentric loads; half the depth for a load on one flange.