Checks

Bearing stiffener

Can the stiffener at a support or under a load carry the force into the web? Where a stiffener is given, it replaces the web crippling check there.

Section G7.1: a compact stiffener is a short column, Pn = min(Fwy·Ac, Fn·Ab), with a strip of web acting with it. Section G7.2: a stud or track fastened to the web of a C-section under two-flange loading, Pn = 0.7(Pwc + Pno) ≥ Pwc.

Specification
AISI S100-24 G7